Related rules (5)
- IncompatibilityThe rule applies only when this part is selected
With 2.5-inch drives the documented range of the 2U HPR heat sink is 165 W-350 W.
Parts on the other side: 2U HPR HSK
Source: dell-r760-tg — page 72
Dell PowerEdge R760 Technical Guide2U HPR HSK 125 W–250 W (supports 3.5-inch drives and non-GPU configuration) 165 W–350 W (supports 2.5-inch drives and non-GPU configuration)
- RequirementThis part is the condition of the rule
Per Dell's cable-routing tables this storage configuration needs one of: PERC H755N, PERC H965i.
Parts on the other side: PERC H755NPERC H965i
Source: dell-r760-ism — page 160
Dell PowerEdge R760 Installation and Service ManualTable 98. 8 x 2.5-inch NVMe RAID with fPERC (H755N)
Source: dell-r760-ism — page 161
Dell PowerEdge R760 Installation and Service ManualTable 99. 8 x 2.5-inch NVMe RAID with fPERC (H965i)
- RequirementThis part is the condition of the rule
16 x 2.5-inch NVMe RAID: two 8-bay NVMe backplanes, each with its own front PERC - per Dell's cable-routing tables two H755N or H965i controllers are needed.
Parts on the other side: PERC H755NPERC H965i
Source: dell-r760-ism — page 163
Dell PowerEdge R760 Installation and Service ManualTable 101. 16 x 2.5-inch NVMe RAID with fPERC (H755N)
Source: dell-r760-ism — page 163
Dell PowerEdge R760 Installation and Service Manual1 SL1_CPU2_PA1 (signal connector on system board) CTRL_DST_PA1 (fPERC input connector)
- No mixingThe rule applies only when this part is selected
16 x 2.5-inch NVMe RAID: Dell's cable-routing tables show only a matching pair (two H755N or two H965i); a mixed H755N + H965i pair is not documented.
Source: dell-r760-ism — page 163
Dell PowerEdge R760 Installation and Service ManualTable 101. 16 x 2.5-inch NVMe RAID with fPERC (H755N)
Source: dell-r760-ism — page 165
Dell PowerEdge R760 Installation and Service ManualTable 103. 16 x 2.5-inch NVMe RAID with fPERC (H965i)
- IncompatibilityThe rule applies only when this part is selected
Riser configuration 8 supports the PERC Adapter only, while this storage configuration's cable tables use front PERCs (fPERC) only.
Parts on the other side: R1B+R2A
Source: dell-r760-tg — page 34
Dell PowerEdge R760 Technical GuideTable 14. PCIe Riser Configurations Config No. Riser configuration No. of Processors PERC type supported Rear storage possible
Source: dell-r760-tg — page 35
Dell PowerEdge R760 Technical Guide8 R1B+R2A 1 PERC Adapter No