Kimia Shop

540-BDDR

PCIe network adapter

Dell SKU

NEBS validated technology device: Intel E810-XXVDA4 Quad Port 10/25GbE SFP28 Adapter, PCIe Full Height

Verified in 1 active model(s): Dell PowerEdge R760

Description

25 Gb PCIe network adapter

A PCIe network adapter with SFP28 ports that supports 25 Gb and usually backward compatibility with 10 Gb.

It suits virtualization clusters, HCI and software-defined storage, which have a lot of east-west traffic.

More bandwidth per port at a cost and power use close to 10 Gb.

This text is the general explanation of this category of part (not a claim about one specific model).

Compatibility map

The relations of this part with other parts, from the audited QuickSpecs rules and the compatibility graph only (every line with its official source).

540-BDDRR1B+R2A+R3B+R4BR1Q+R2A+R3B+R4QR1P+R2A+R3B+R4P (HL)R1P+R2A+R3B+R4P (FL)R1P+R2A+R3B+R4R (HL)R1R+R2A+R3A+R4P (HL)R1R+R2A+R3A+R4P (FL)R2A+R4QR1Q+R2A+R4QR1B+R2AR1Q+R2A+R4RR1P+R2A+R4R (HL)R1P+R2A+R4R (FL)R1 Paddle + R2A + R3B + R4 Paddle

Click a part or a relation line (or press Enter) to pin its explanation and source; Esc releases it. Drag to pan the map or use the arrow keys; zoom with the buttons, the + and − keys or Ctrl with the mouse wheel.

Hover or click a part or a relation to show its recorded rule and official source.

  • Requires: 540-BDDR requires R1B+R2A+R3B+R4B. PCIe NICs (540-BDIW / 540-BDDR, full height) install in a riser PCIe slot: select a riser configuration with slots (configuration 0 has none).
  • Requires: 540-BDDR requires R1Q+R2A+R3B+R4Q. PCIe NICs (540-BDIW / 540-BDDR, full height) install in a riser PCIe slot: select a riser configuration with slots (configuration 0 has none).
  • Requires: 540-BDDR requires R1P+R2A+R3B+R4P (HL). PCIe NICs (540-BDIW / 540-BDDR, full height) install in a riser PCIe slot: select a riser configuration with slots (configuration 0 has none).
  • Requires: 540-BDDR requires R1P+R2A+R3B+R4P (FL). PCIe NICs (540-BDIW / 540-BDDR, full height) install in a riser PCIe slot: select a riser configuration with slots (configuration 0 has none).
  • Requires: 540-BDDR requires R1P+R2A+R3B+R4R (HL). PCIe NICs (540-BDIW / 540-BDDR, full height) install in a riser PCIe slot: select a riser configuration with slots (configuration 0 has none).
  • Requires: 540-BDDR requires R1R+R2A+R3A+R4P (HL). PCIe NICs (540-BDIW / 540-BDDR, full height) install in a riser PCIe slot: select a riser configuration with slots (configuration 0 has none).
  • Requires: 540-BDDR requires R1R+R2A+R3A+R4P (FL). PCIe NICs (540-BDIW / 540-BDDR, full height) install in a riser PCIe slot: select a riser configuration with slots (configuration 0 has none).
  • Requires: 540-BDDR requires R2A+R4Q. PCIe NICs (540-BDIW / 540-BDDR, full height) install in a riser PCIe slot: select a riser configuration with slots (configuration 0 has none).
  • Requires: 540-BDDR requires R1Q+R2A+R4Q. PCIe NICs (540-BDIW / 540-BDDR, full height) install in a riser PCIe slot: select a riser configuration with slots (configuration 0 has none).
  • Requires: 540-BDDR requires R1B+R2A. PCIe NICs (540-BDIW / 540-BDDR, full height) install in a riser PCIe slot: select a riser configuration with slots (configuration 0 has none).
  • Requires: 540-BDDR requires R1Q+R2A+R4R. PCIe NICs (540-BDIW / 540-BDDR, full height) install in a riser PCIe slot: select a riser configuration with slots (configuration 0 has none).
  • Requires: 540-BDDR requires R1P+R2A+R4R (HL). PCIe NICs (540-BDIW / 540-BDDR, full height) install in a riser PCIe slot: select a riser configuration with slots (configuration 0 has none).
  • Requires: 540-BDDR requires R1P+R2A+R4R (FL). PCIe NICs (540-BDIW / 540-BDDR, full height) install in a riser PCIe slot: select a riser configuration with slots (configuration 0 has none).
  • Requires: 540-BDDR requires R1 Paddle + R2A + R3B + R4 Paddle. PCIe NICs (540-BDIW / 540-BDDR, full height) install in a riser PCIe slot: select a riser configuration with slots (configuration 0 has none).

Active models in which this part is listed

Dell PowerEdge R760

step «Networking»Add to this model's configuration

Related rules (34)

  • Maximum quantityThe rule limits this part

    These cards are not listed in the card table of riser configuration 0 (NO RSR) in Dell's ISM and are not supported with it.

    Source: dell-r760-ism — page 260
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 260View documentSearch this document
    Table 154. Configuration 0: No risers
    Source: dell-r760-ism — page 260
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 260View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    With the selected riser configuration Dell's card tables allow at most 1 x 540-BDDR.

    Source: dell-r760-ism — page 271
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 271View documentSearch this document
    Intel (NIC: 25Gb) 2 1
    Source: dell-r760-ism — page 279
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 279View documentSearch this document
    Intel (NIC: 25Gb) 7 1
  • Maximum quantityThe rule limits this part

    With the selected riser configuration Dell's card tables allow at most 2 x 540-BDDR.

    Source: dell-r760-ism — page 266
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 266View documentSearch this document
    Intel (NIC: 25Gb) 7, 2 2
    Source: dell-r760-ism — page 269
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 269View documentSearch this document
    Intel (NIC: 25Gb) 7, 2 2
  • Maximum quantityThe rule limits this part

    With the selected riser configuration Dell's card tables allow at most 3 x 540-BDDR.

    Source: dell-r760-ism — page 281
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 281View documentSearch this document
    Intel (NIC: 25Gb) 7, 1, 2 3
    Source: dell-r760-ism — page 285
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 285View documentSearch this document
    Intel (NIC: 25Gb) 7, 1, 2 3
  • Maximum quantityThe rule limits this part

    With the selected riser configuration Dell's card tables allow at most 4 x 540-BDDR.

    Source: dell-r760-ism — page 274
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 274View documentSearch this document
    Intel (NIC: 25Gb) 5, 7, 1, 2 4
    Source: dell-r760-ism — page 277
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 277View documentSearch this document
    Intel (NIC: 25Gb) 5, 7, 1, 2 4
  • Maximum quantityThe rule limits this part

    Riser configuration 1: per Dell's card tables these cards install only in slot(s) 7, 5, 4, 2, 1; at most 5 in total.

    Source: dell-r760-ism — page 260
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 260View documentSearch this document
    Table 155. Configuration 1: R1B+R2A+R3B+R4B
    Source: dell-r760-ism — page 260
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 260View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    Riser configuration 2: per Dell's card tables these cards install only in slot(s) 7, 5, 4, 2, 1; at most 5 in total.

    Source: dell-r760-ism — page 262
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 262View documentSearch this document
    Table 156. Configuration 2: R1Q+R2A+R3B+R4Q
    Source: dell-r760-ism — page 262
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 262View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    Riser configuration 3-1: per Dell's card tables these cards install only in slot(s) 7, 2 (540-BDDR: the Intel 25Gb row with the lowest maximum, conservative reading); at most 2 in total.

    Source: dell-r760-ism — page 264
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 264View documentSearch this document
    Table 157. Configuration 3-1: R1P+R2A+R3B+R4P (HL)
    Source: dell-r760-ism — page 264
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 264View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    Riser configuration 3-2: per Dell's card tables these cards install only in slot(s) 7, 2 (540-BDDR: the Intel 25Gb row with the lowest maximum, conservative reading); at most 2 in total.

    Source: dell-r760-ism — page 267
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 267View documentSearch this document
    Table 158. Configuration 3-2: R1P+R2A+R3B+R4P (FL)
    Source: dell-r760-ism — page 267
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 267View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    Riser configuration 4-1: per Dell's card tables these cards install only in slot(s) 2 (540-BDDR: the Intel 25Gb row with the lowest maximum, conservative reading); at most 1 in total.

    Source: dell-r760-ism — page 270
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 270View documentSearch this document
    Table 159. Configuration 4-1: R1P+R2A+R3B+R4R (HL)
    Source: dell-r760-ism — page 270
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 270View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    Riser configuration 4-1: per Dell's card tables these cards install only in slot(s) 5, 4, 2 (540-BDDR: the Intel 25Gb row with the lowest maximum, conservative reading); at most 3 in total.

    Source: dell-r760-ism — page 270
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 270View documentSearch this document
    Table 159. Configuration 4-1: R1P+R2A+R3B+R4R (HL)
    Source: dell-r760-ism — page 270
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 270View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    Riser configuration 6: per Dell's card tables these cards install only in slot(s) 7; at most 1 in total.

    Source: dell-r760-ism — page 278
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 278View documentSearch this document
    Table 162. Configuration 6: R2A+R4Q
    Source: dell-r760-ism — page 278
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 278View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    Riser configuration 7/12: per Dell's card tables these cards install only in slot(s) 7, 2, 1; at most 3 in total.

    Source: dell-r760-ism — page 280
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 280View documentSearch this document
    Table 163. Configuration 7: R1Q+R2A+R4Q
    Source: dell-r760-ism — page 280
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 280View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    Riser configuration 10-1: per Dell's card tables these cards install only in slot(s) 2 (540-BDDR: the Intel 25Gb row with the lowest maximum, conservative reading); at most 1 in total.

    Source: dell-r760-ism — page 286
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 286View documentSearch this document
    Table 166. Configuration 10-1: R1P+R2A+R4R (HL)
    Source: dell-r760-ism — page 286
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 286View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    Riser configuration 10-2: per Dell's card tables these cards install only in slot(s) 2 (540-BDDR: the Intel 25Gb row with the lowest maximum, conservative reading); at most 1 in total.

    Source: dell-r760-ism — page 288
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 288View documentSearch this document
    Table 167. Configuration 10-2: R1P+R2A+R4R (FL)
    Source: dell-r760-ism — page 288
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 288View documentSearch this document
    Card type Slot priority Maximum number of cards
  • RequirementThis part is the condition of the rule

    PCIe NICs (540-BDIW / 540-BDDR, full height) install in a riser PCIe slot: select a riser configuration with slots (configuration 0 has none).

    Parts on the other side: R1B+R2A+R3B+R4BR1Q+R2A+R3B+R4QR1P+R2A+R3B+R4P (HL)R1P+R2A+R3B+R4P (FL)R1P+R2A+R3B+R4R (HL)R1R+R2A+R3A+R4P (HL)R1R+R2A+R3A+R4P (FL)R2A+R4QR1Q+R2A+R4QR1B+R2AR1Q+R2A+R4RR1P+R2A+R4R (HL)

    Source: dell-r760-tg — page 92
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 92View documentSearch this document
    Intel Ethernet i350 Quad Port 1 GbE BASE-T Adapter, PCIe Full Height, V2, FIRMWARE RESTRICTIONS APPLY [540-BDIW]
    Source: dell-r760-tg — page 92
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 92View documentSearch this document
    Intel E810-XXVDA4 Quad Port 10/25GbE SFP28 Adapter, PCIe Full Height [540-BDDR]
  • Maximum quantityThe rule limits this part

    Per Dell's card tables no riser configuration supports more than 5 x 540-BDDR.

    Source: dell-r760-ism — page 260
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 260View documentSearch this document
    Table 155. Configuration 1: R1B+R2A+R3B+R4B
    Source: dell-r760-ism — page 260
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 260View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    The selected riser configuration (0) has 0 PCIe slot(s) (ISM Table 153): GPUs + PCIe NICs + external controllers <= 0.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    The selected riser configuration (8, 10-1, 10-2) has 3 PCIe slot(s) (ISM Table 153): GPUs + PCIe NICs + external controllers <= 3.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 8, 10-1, 10-2 slot cards + adapter <= 3.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    Front + adapter dual-controller base: with riser configuration 8, 10-1, 10-2 slot cards + internal controllers <= 4 (3 slots + the front PERC's integrated slot).

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    The selected riser configuration (6, 9, 11) has 4 PCIe slot(s) (ISM Table 153): GPUs + PCIe NICs + external controllers <= 4.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 6, 9, 11 slot cards + adapter <= 4.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    Front + adapter dual-controller base: with riser configuration 6, 9, 11 slot cards + internal controllers <= 5 (4 slots + the front PERC's integrated slot).

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    The selected riser configuration (3-1, 3-2, 4-1, 5-1, 5-2, 7/12) has 6 PCIe slot(s) (ISM Table 153): GPUs + PCIe NICs + external controllers <= 6.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 3-1, 3-2, 4-1, 5-1, 5-2, 7/12 slot cards + adapter <= 6.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    Front + adapter dual-controller base: with riser configuration 3-1, 3-2, 4-1, 5-1, 5-2, 7/12 slot cards + internal controllers <= 7 (6 slots + the front PERC's integrated slot).

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    The selected riser configuration (1, 2) has 8 PCIe slot(s) (ISM Table 153): GPUs + PCIe NICs + external controllers <= 8.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 1, 2 slot cards + adapter <= 8.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    Front + adapter dual-controller base: with riser configuration 1, 2 slot cards + internal controllers <= 9 (8 slots + the front PERC's integrated slot).

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    The selected riser configuration (6, 8, 10-1, 10-2, 11) has 2 full-height slot(s) (Table 153): GPUs + full-height PCIe NICs <= 2.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    The selected riser configuration (9) has 3 full-height slot(s) (Table 153): GPUs + full-height PCIe NICs <= 3.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    The selected riser configuration (3-1, 3-2, 4-1, 5-1, 5-2, 7/12) has 4 full-height slot(s) (Table 153): GPUs + full-height PCIe NICs <= 4.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    The selected riser configuration (1, 2) has 6 full-height slot(s) (Table 153): GPUs + full-height PCIe NICs <= 6.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor

Verification and sources

Verified against this option's row in Dell's official documents; Dell publishes no part number for it - the orderable SKU and price come from a Dell quote.

Document row: dell-r760-tg — page 92
Dell PowerEdge R760 Technical Guide
“dell-r760-tg” — page 92View documentSearch this document
Intel E810-XXVDA4 Quad Port 10/25GbE SFP28 Adapter, PCIe Full Height [540-BDDR]

This page contains only the audited data of the official vendor documents (HPE, Lenovo, Dell) for the active models. Price and availability are given through the quote request in the configurator.