Related rules (21)
- RequirementThis part can satisfy the requirement of the rule
Per Dell's cable-routing tables this storage configuration needs one of: PERC H755, PERC H355, HBA355i, PERC H965i, HBA465i.
Parts on the other side: 12 x 3.5" (SAS/SATA)12 x 3.5" (SAS/SATA) w/ rear 2 x 2.5" (SAS/SATA)12 x 3.5" (SAS/SATA) w/ rear 2 x 2.5" NVMe Direct12 x 3.5" (SAS/SATA) + 4 x 2.5" (SAS/SATA)12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct)
Source: dell-r760-ism — page 154
Dell PowerEdge R760 Installation and Service ManualTable 92. 12 x 3.5-inch SAS/SATA with APERC11/12 in Riser 2
Source: dell-r760-ism — page 157
Dell PowerEdge R760 Installation and Service ManualTable 95. 12 x 3.5-inch SAS/SATA + 4 x 2.5-inch SAS/SATA with APERC11/12 in Riser 2
- No mixingThe rule limits this part
16 x 2.5-inch NVMe RAID: Dell's cable-routing tables show only a matching pair (two H755N or two H965i); a mixed H755N + H965i pair is not documented.
Source: dell-r760-ism — page 163
Dell PowerEdge R760 Installation and Service ManualTable 101. 16 x 2.5-inch NVMe RAID with fPERC (H755N)
Source: dell-r760-ism — page 165
Dell PowerEdge R760 Installation and Service ManualTable 103. 16 x 2.5-inch NVMe RAID with fPERC (H965i)
- Maximum quantityThe rule limits this part
At most two internal storage controllers: Dell's cable-routing configurations use at most two (dual-controller configurations).
Source: dell-r760-ism — page 177
Dell PowerEdge R760 Installation and Service ManualTable 116. 24 x 2.5-inch SAS/SATA dual controller with fPERC (H965i) and APERC in Riser 2
Source: dell-r760-ism — page 199
Dell PowerEdge R760 Installation and Service ManualTable 138. 16 x EDSFF E3.S NVMe with dual fPERC (H965i)
- Maximum quantityThe rule limits this part
Dell's cable-routing tables for this storage configuration route one front PERC (fPERC) only: at most one internal storage controller (two only on the dual-controller and 16 x 2.5-inch NVMe RAID configurations).
Source: dell-r760-ism — page 181
Dell PowerEdge R760 Installation and Service ManualTable 120. 24 x 2.5-inch SAS/SATA with fPERC (HBA355i, H355, H755)
Source: dell-r760-ism — page 172
Dell PowerEdge R760 Installation and Service ManualTable 111. 24 x 2.5-inch SAS/SATA with fPERC (H965i)
- IncompatibilityThis part is one side of an incompatibility
Riser configuration 8 supports the PERC Adapter only, while this storage configuration's cable tables use front PERCs (fPERC) only.
Parts on the other side: R1B+R2A
Source: dell-r760-tg — page 34
Dell PowerEdge R760 Technical GuideTable 14. PCIe Riser Configurations Config No. Riser configuration No. of Processors PERC type supported Rear storage possible
Source: dell-r760-tg — page 35
Dell PowerEdge R760 Technical Guide8 R1B+R2A 1 PERC Adapter No
- Maximum quantityThe rule limits this part
These cards are not listed in the card table of riser configuration 8 (R1B+R2A) in Dell's ISM and are not supported with it.
Source: dell-r760-ism — page 282
Dell PowerEdge R760 Installation and Service ManualTable 164. Configuration 8: R1B+R2A
Source: dell-r760-ism — page 282
Dell PowerEdge R760 Installation and Service ManualCard type Slot priority Maximum number of cards
- Maximum quantityThe rule limits this part
These cards are not listed in the card table of riser configuration 9 (R1Q+R2A+R4R) in Dell's ISM and are not supported with it.
Source: dell-r760-ism — page 284
Dell PowerEdge R760 Installation and Service ManualTable 165. Configuration 9: R1Q+R2A+R4R
Source: dell-r760-ism — page 284
Dell PowerEdge R760 Installation and Service ManualCard type Slot priority Maximum number of cards
- Maximum quantityThe rule limits this part
These cards are not listed in the card table of riser configuration 10-1 (R1P+R2A+R4R (HL)) in Dell's ISM and are not supported with it.
Source: dell-r760-ism — page 286
Dell PowerEdge R760 Installation and Service ManualTable 166. Configuration 10-1: R1P+R2A+R4R (HL)
Source: dell-r760-ism — page 286
Dell PowerEdge R760 Installation and Service ManualCard type Slot priority Maximum number of cards
- Maximum quantityThe rule limits this part
These cards are not listed in the card table of riser configuration 10-2 (R1P+R2A+R4R (FL)) in Dell's ISM and are not supported with it.
Source: dell-r760-ism — page 288
Dell PowerEdge R760 Installation and Service ManualTable 167. Configuration 10-2: R1P+R2A+R4R (FL)
Source: dell-r760-ism — page 288
Dell PowerEdge R760 Installation and Service ManualCard type Slot priority Maximum number of cards
- Maximum quantityThe rule limits this part
These cards are not listed in the card table of riser configuration 11 (R1 Paddle + R2A + R3B + R4 Paddle) in Dell's ISM and are not supported with it.
Source: dell-r760-ism — page 291
Dell PowerEdge R760 Installation and Service ManualTable 168. Configuration 11: R1 paddle+R2A+R3B+R4 paddle
Source: dell-r760-ism — page 291
Dell PowerEdge R760 Installation and Service ManualCard type Slot priority Maximum number of cards
- Maximum quantityThe rule limits this part
With the selected riser configuration Dell's card tables allow at most 1 x HBA465i.
Source: dell-r760-ism — page 260
Dell PowerEdge R760 Installation and Service ManualFoxconn (Front PERC12 HBA465i) Integrated slot 1
- RequirementThis part is the condition of the rule
The allowed number and position of storage controllers (front PERC / PERC Adapter) depend on the riser configuration: select it (or configuration 0 'NO RSR').
Source: dell-r760-tg — page 34
Dell PowerEdge R760 Technical GuideTable 14. PCIe Riser Configurations Config No. Riser configuration No. of Processors PERC type supported Rear storage possible
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
- Maximum quantityThe rule limits this part
12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 8, 10-1, 10-2 slot cards + adapter <= 3.
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule limits this part
Front + adapter dual-controller base: with riser configuration 8, 10-1, 10-2 slot cards + internal controllers <= 4 (3 slots + the front PERC's integrated slot).
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule limits this part
12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 6, 9, 11 slot cards + adapter <= 4.
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule limits this part
Front + adapter dual-controller base: with riser configuration 6, 9, 11 slot cards + internal controllers <= 5 (4 slots + the front PERC's integrated slot).
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule limits this part
12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 3-1, 3-2, 4-1, 5-1, 5-2, 7/12 slot cards + adapter <= 6.
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule limits this part
Front + adapter dual-controller base: with riser configuration 3-1, 3-2, 4-1, 5-1, 5-2, 7/12 slot cards + internal controllers <= 7 (6 slots + the front PERC's integrated slot).
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule limits this part
12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 1, 2 slot cards + adapter <= 8.
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule limits this part
Front + adapter dual-controller base: with riser configuration 1, 2 slot cards + internal controllers <= 9 (8 slots + the front PERC's integrated slot).
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- WarningThe rule applies only when this part is selected
This option needs expert review (see the item note).
Source: dell-r760-ism — page 39
Dell PowerEdge R760 Installation and Service ManualNOTE: See the Thermal restriction matrix for required fan support with air cooled and DLC configurations.
Source: dell-r760-tg — page 20
Dell PowerEdge R760 Technical GuideNOTE: 6400/5600 MT/s RDIMMs are applicable for 5th Gen Intel® Xeon® Scalable Processors.