Kimia Shop

12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct)

Base modelNeeds expert review

Dell option (no published part number)

Internal storage configuration: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct)

Verified in 1 active model(s): Dell PowerEdge R760

Description

Base with LFF cage (3.5-inch drives)

A chassis with LFF (Large Form Factor) front bays for 3.5-inch drives, which have the highest capacity per drive.

For bulk storage, backup, archive and video, where capacity matters more than IOPS, LFF lowers the cost per terabyte.

High raw capacity is reached with fewer drives and less power per terabyte.

This text is the general explanation of this category of part (not a claim about one specific model).

Attributes (extracted from the official description)

SFF bays
4
LFF bays
12
EDSFF bays
0
SAS/SATA bays
0
NVMe bays
4

Compatibility map

The relations of this part with other parts, from the audited QuickSpecs rules and the compatibility graph only (every line with its official source).

12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct)STD HSKNO RSRR1B+R2A+R3B+R4BR1Q+R2A+R3B+R4QR1P+R2A+R3B+R4P (HL)R1P+R2A+R3B+R4P (FL)R1P+R2A+R3B+R4R (HL)R1R+R2A+R3A+R4P (HL)R1R+R2A+R3A+R4P (FL)R1B+R2AR1Q+R2A+R4RR1P+R2A+R4R (HL)R1P+R2A+R4R (FL)R1 Paddle + R2A + R3B + R4 Paddle

Click a part or a relation line (or press Enter) to pin its explanation and source; Esc releases it. Drag to pan the map or use the arrow keys; zoom with the buttons, the + and − keys or Ctrl with the mouse wheel. 13 more related part(s) were left off the map for legibility; the rule list on this page is more complete.

Hover or click a part or a relation to show its recorded rule and official source.

  • Incompatible: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) and STD HSK are incompatible. The STD heat sink supports only 2.5-inch drive configurations.
  • Incompatible: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) and NO RSR are incompatible. Rear storage is possible only with riser configurations 6, 7 and 12.
  • Incompatible: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) and R1B+R2A+R3B+R4B are incompatible. Rear storage is possible only with riser configurations 6, 7 and 12.
  • Requires: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) requires R1B+R2A+R3B+R4B. 12 x 3.5-inch configurations use an adapter PERC in Riser 2: only riser configurations supporting 'PERC Adapter' (1-8, 12) are allowed - not 0, 9, 10 or 11.
  • Incompatible: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) and R1Q+R2A+R3B+R4Q are incompatible. Rear storage is possible only with riser configurations 6, 7 and 12.
  • Requires: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) requires R1Q+R2A+R3B+R4Q. 12 x 3.5-inch configurations use an adapter PERC in Riser 2: only riser configurations supporting 'PERC Adapter' (1-8, 12) are allowed - not 0, 9, 10 or 11.
  • Incompatible: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) and R1P+R2A+R3B+R4P (HL) are incompatible. Rear storage is possible only with riser configurations 6, 7 and 12.
  • Requires: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) requires R1P+R2A+R3B+R4P (HL). 12 x 3.5-inch configurations use an adapter PERC in Riser 2: only riser configurations supporting 'PERC Adapter' (1-8, 12) are allowed - not 0, 9, 10 or 11.
  • Incompatible: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) and R1P+R2A+R3B+R4P (FL) are incompatible. Rear storage is possible only with riser configurations 6, 7 and 12.
  • Requires: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) requires R1P+R2A+R3B+R4P (FL). 12 x 3.5-inch configurations use an adapter PERC in Riser 2: only riser configurations supporting 'PERC Adapter' (1-8, 12) are allowed - not 0, 9, 10 or 11.
  • Incompatible: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) and R1P+R2A+R3B+R4R (HL) are incompatible. Rear storage is possible only with riser configurations 6, 7 and 12.
  • Requires: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) requires R1P+R2A+R3B+R4R (HL). 12 x 3.5-inch configurations use an adapter PERC in Riser 2: only riser configurations supporting 'PERC Adapter' (1-8, 12) are allowed - not 0, 9, 10 or 11.
  • Incompatible: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) and R1R+R2A+R3A+R4P (HL) are incompatible. Rear storage is possible only with riser configurations 6, 7 and 12.
  • Requires: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) requires R1R+R2A+R3A+R4P (HL). 12 x 3.5-inch configurations use an adapter PERC in Riser 2: only riser configurations supporting 'PERC Adapter' (1-8, 12) are allowed - not 0, 9, 10 or 11.
  • Incompatible: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) and R1R+R2A+R3A+R4P (FL) are incompatible. Rear storage is possible only with riser configurations 6, 7 and 12.
  • Requires: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) requires R1R+R2A+R3A+R4P (FL). 12 x 3.5-inch configurations use an adapter PERC in Riser 2: only riser configurations supporting 'PERC Adapter' (1-8, 12) are allowed - not 0, 9, 10 or 11.
  • Incompatible: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) and R1B+R2A are incompatible. Rear storage is possible only with riser configurations 6, 7 and 12.
  • Requires: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) requires R1B+R2A. 12 x 3.5-inch configurations use an adapter PERC in Riser 2: only riser configurations supporting 'PERC Adapter' (1-8, 12) are allowed - not 0, 9, 10 or 11.
  • Incompatible: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) and R1Q+R2A+R4R are incompatible. Rear storage is possible only with riser configurations 6, 7 and 12.
  • Incompatible: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) and R1P+R2A+R4R (HL) are incompatible. Rear storage is possible only with riser configurations 6, 7 and 12.
  • Incompatible: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) and R1P+R2A+R4R (FL) are incompatible. Rear storage is possible only with riser configurations 6, 7 and 12.
  • Incompatible: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) and R1 Paddle + R2A + R3B + R4 Paddle are incompatible. Rear storage is possible only with riser configurations 6, 7 and 12.

Active models in which this part is listed

Dell PowerEdge R760

step «Chassis / storage configuration»Add to this model's configuration

Related rules (15)

  • IncompatibilityThis part is one side of an incompatibility

    The STD heat sink supports only 2.5-inch drive configurations.

    Parts on the other side: STD HSK

    Source: dell-r760-tg — page 72
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 72View documentSearch this document
    STD HSK ≤ 165 W (supports only 2.5-inch drives and non-GPU configuration)
  • IncompatibilityThe rule applies only when this part is selected

    With 3.5-inch drives the 2U HPR heat sink supports 125 W-250 W processors.

    Parts on the other side: 2U HPR HSK

    Source: dell-r760-tg — page 72
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 72View documentSearch this document
    2U HPR HSK 125 W–250 W (supports 3.5-inch drives and non-GPU configuration) 165 W–350 W (supports 2.5-inch drives and non-GPU configuration)
  • RequirementThe rule applies only when this part is selected

    12 x 3.5-inch configurations (with or without rear drives): processors of 270 W and above are 'Required DLC' in Dell's thermal matrices - one DLC module per processor.

    Source: dell-r760-tg — page 73
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 73View documentSearch this document
    Table 40. Thermal restriction matrix for air cooled configuration
    Source: dell-r760-tg — page 74
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 74View documentSearch this document
    6444Y 270 W² 32 75 HPR SLVR HPR SLV R HPR SLVR HPR SLVR HP R SL VR HPR SLVR HPR SLVR HPR GOL D Req uire d DLC Require d DLC 35°C (95°F)
  • IncompatibilityThis part is one side of an incompatibility

    12 x 3.5-inch with a rear module: CPU TDP greater than 270 W and specific Low Temperature-case CPUs are not supported.

    Source: dell-r760-ism — page 51
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 51View documentSearch this document
    NOTE: In 12 x 3.5-inch with rear module configuration, for CPU TDP greater than 270 W and specific Low Temperature- case CPUs are not supported.
  • WarningThe rule applies only when this part is selected

    Dell states that specific Low Temperature-case CPUs are not supported in 12 x 3.5-inch with a rear module, without naming them - confirm the processor with an expert.

    Source: dell-r760-ism — page 51
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 51View documentSearch this document
    NOTE: In 12 x 3.5-inch with rear module configuration, for CPU TDP greater than 270 W and specific Low Temperature- case CPUs are not supported.
  • RequirementThis part is the condition of the rule

    Per Dell's cable-routing tables this storage configuration needs one of: PERC H755, PERC H355, HBA355i, PERC H965i, HBA465i.

    Parts on the other side: PERC H755PERC H355HBA355iPERC H965iHBA465i

    Source: dell-r760-ism — page 154
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 154View documentSearch this document
    Table 92. 12 x 3.5-inch SAS/SATA with APERC11/12 in Riser 2
    Source: dell-r760-ism — page 157
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 157View documentSearch this document
    Table 95. 12 x 3.5-inch SAS/SATA + 4 x 2.5-inch SAS/SATA with APERC11/12 in Riser 2
  • IncompatibilityThis part is one side of an incompatibility

    Rear storage is possible only with riser configurations 6, 7 and 12.

    Parts on the other side: NO RSRR1B+R2A+R3B+R4BR1Q+R2A+R3B+R4QR1P+R2A+R3B+R4P (HL)R1P+R2A+R3B+R4P (FL)R1P+R2A+R3B+R4R (HL)R1R+R2A+R3A+R4P (HL)R1R+R2A+R3A+R4P (FL)R1B+R2AR1Q+R2A+R4RR1P+R2A+R4R (HL)R1P+R2A+R4R (FL)

    Source: dell-r760-tg — page 34
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 34View documentSearch this document
    Table 14. PCIe Riser Configurations Config No. Riser configuration No. of Processors PERC type supported Rear storage possible
    Source: dell-r760-tg — page 34
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 34View documentSearch this document
    6 R2A+R4Q 2 Front PERC/PERC Adapter Yes
  • RequirementThis part is the condition of the rule

    A rear-drive configuration is possible only with riser configuration 6, 7 or 12; select one of them.

    Parts on the other side: R2A+R4QR1Q+R2A+R4Q

    Source: dell-r760-tg — page 34
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 34View documentSearch this document
    Table 14. PCIe Riser Configurations Config No. Riser configuration No. of Processors PERC type supported Rear storage possible
    Source: dell-r760-tg — page 34
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 34View documentSearch this document
    6 R2A+R4Q 2 Front PERC/PERC Adapter Yes
  • RequirementThis part is the condition of the rule

    12 x 3.5-inch configurations use an adapter PERC in Riser 2: only riser configurations supporting 'PERC Adapter' (1-8, 12) are allowed - not 0, 9, 10 or 11.

    Parts on the other side: R1B+R2A+R3B+R4BR1Q+R2A+R3B+R4QR1P+R2A+R3B+R4P (HL)R1P+R2A+R3B+R4P (FL)R1P+R2A+R3B+R4R (HL)R1R+R2A+R3A+R4P (HL)R1R+R2A+R3A+R4P (FL)R2A+R4QR1Q+R2A+R4QR1B+R2A

    Source: dell-r760-ism — page 154
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 154View documentSearch this document
    Table 92. 12 x 3.5-inch SAS/SATA with APERC11/12 in Riser 2
    Source: dell-r760-ism — page 203
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 203View documentSearch this document
    Table 142. 12 x 3.5-inch SAS/SATA + 4 x EDSFF E3.S with APERC11 in Riser 2
  • IncompatibilityThis part is one side of an incompatibility

    12 x 3.5-inch and rear-drive configurations do not support a GPU card.

    Source: dell-r760-ism — page 369
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 369View documentSearch this document
    NOTE: 12 x 3.5-inch and rear drive configuration systems do not support a GPU card.
  • Maximum quantityThe rule applies only when this part is selected

    12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 8, 10-1, 10-2 slot cards + adapter <= 3.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule applies only when this part is selected

    12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 6, 9, 11 slot cards + adapter <= 4.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule applies only when this part is selected

    12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 3-1, 3-2, 4-1, 5-1, 5-2, 7/12 slot cards + adapter <= 6.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule applies only when this part is selected

    12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 1, 2 slot cards + adapter <= 8.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • WarningThe rule applies only when this part is selected

    This option needs expert review (see the item note).

    Source: dell-r760-ism — page 39
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 39View documentSearch this document
    NOTE: See the Thermal restriction matrix for required fan support with air cooled and DLC configurations.
    Source: dell-r760-tg — page 20
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 20View documentSearch this document
    NOTE: 6400/5600 MT/s RDIMMs are applicable for 5th Gen Intel® Xeon® Scalable Processors.

Verification and sources

Verified against this option's row in Dell's official documents; Dell publishes no part number for it - the orderable SKU and price come from a Dell quote.

Document row: dell-r760-tg — page 22
Dell PowerEdge R760 Technical Guide
“dell-r760-tg” — page 22View documentSearch this document
12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct)

This page contains only the audited data of the official vendor documents (HPE, Lenovo, Dell) for the active models. Price and availability are given through the quote request in the configurator.