Compatibility map

The relations of this part with other parts, from the audited QuickSpecs rules and the compatibility graph only (every line with its official source).

HBA355iR1B+R2A12 x 3.5" (SAS/SATA)12 x 3.5" (SAS/SATA) w/ rear 2 x 2.5" (SAS/SATA)12 x 3.5" (SAS/SATA) w/ rear 2 x 2.5" NVMe Direct12 x 3.5" (SAS/SATA) + 4 x 2.5" (SAS/SATA)12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct)12 x 3.5" (SAS/SATA) + 4 x EDSFF E3.S (Gen5 x 4 NVMe Direct)8 x 2.5" Universal (SAS/SATA HWRAID + NVMe Direct)16 x 2.5" (SAS4/SATA) Smart Flow16 x 2.5"(SAS4/SATA)+ 8 x 2.5" NVMe Direct24 x 2.5" (SAS4/SATA) with 8 x Universal slots (SAS/SATA HWRAID + NVMe Direct)24 x 2.5" (SAS4/SATA)24 x 2.5" (SAS4/SATA) + 2 x 2.5" (NVMe Direct)24 x 2.5"(SAS4/SATA) + 2 x 2.5" (SAS/SATA)

Click a part or a relation line (or press Enter) to pin its explanation and source; Esc releases it. Drag to pan the map or use the arrow keys; zoom with the buttons, the + and − keys or Ctrl with the mouse wheel. 7 more related part(s) were left off the map for legibility; the rule list on this page is more complete.

Hover or click a part or a relation to show its recorded rule and official source.

  • Incompatible: HBA355i and R1B+R2A are incompatible. Riser configuration 8 supports the PERC Adapter only, while this storage configuration's cable tables use front PERCs (fPERC) only.
  • Requires: 12 x 3.5" (SAS/SATA) requires HBA355i. Per Dell's cable-routing tables this storage configuration needs one of: PERC H755, PERC H355, HBA355i, PERC H965i, HBA465i.
  • Requires: 12 x 3.5" (SAS/SATA) w/ rear 2 x 2.5" (SAS/SATA) requires HBA355i. Per Dell's cable-routing tables this storage configuration needs one of: PERC H755, PERC H355, HBA355i, PERC H965i, HBA465i.
  • Requires: 12 x 3.5" (SAS/SATA) w/ rear 2 x 2.5" NVMe Direct requires HBA355i. Per Dell's cable-routing tables this storage configuration needs one of: PERC H755, PERC H355, HBA355i, PERC H965i, HBA465i.
  • Requires: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (SAS/SATA) requires HBA355i. Per Dell's cable-routing tables this storage configuration needs one of: PERC H755, PERC H355, HBA355i, PERC H965i, HBA465i.
  • Requires: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) requires HBA355i. Per Dell's cable-routing tables this storage configuration needs one of: PERC H755, PERC H355, HBA355i, PERC H965i, HBA465i.
  • Requires: 12 x 3.5" (SAS/SATA) + 4 x EDSFF E3.S (Gen5 x 4 NVMe Direct) requires HBA355i. Per Dell's cable-routing tables this storage configuration needs one of: PERC H755, PERC H355, HBA355i.
  • Requires: 8 x 2.5" Universal (SAS/SATA HWRAID + NVMe Direct) requires HBA355i. Per Dell's cable-routing tables this storage configuration needs one of: HBA355i, PERC H355, PERC H755, PERC H965i.
  • Requires: 16 x 2.5" (SAS4/SATA) Smart Flow requires HBA355i. Per Dell's cable-routing tables this storage configuration needs one of: HBA355i, PERC H355, PERC H755, PERC H965i.
  • Requires: 16 x 2.5"(SAS4/SATA)+ 8 x 2.5" NVMe Direct requires HBA355i. Per Dell's cable-routing tables this storage configuration needs one of: HBA355i, PERC H355, PERC H755, PERC H965i.
  • Requires: 24 x 2.5" (SAS4/SATA) with 8 x Universal slots (SAS/SATA HWRAID + NVMe Direct) requires HBA355i. Per Dell's cable-routing tables this storage configuration needs one of: HBA355i, PERC H355, PERC H755, PERC H965i.
  • Requires: 24 x 2.5" (SAS4/SATA) requires HBA355i. Per Dell's cable-routing tables this storage configuration needs one of: HBA355i, PERC H355, PERC H755, PERC H965i.
  • Requires: 24 x 2.5" (SAS4/SATA) + 2 x 2.5" (NVMe Direct) requires HBA355i. Per Dell's cable-routing tables this storage configuration needs one of: HBA355i, PERC H355, PERC H755, PERC H965i.
  • Requires: 24 x 2.5"(SAS4/SATA) + 2 x 2.5" (SAS/SATA) requires HBA355i. Per Dell's cable-routing tables this storage configuration needs one of: HBA355i, PERC H355, PERC H755, PERC H965i.

Active models in which this part is listed

Dell PowerEdge R760

step «Storage controllers»Add to this model's configuration

Related rules (29)

  • RequirementThis part can satisfy the requirement of the rule

    Per Dell's cable-routing tables this storage configuration needs one of: PERC H755, PERC H355, HBA355i, PERC H965i, HBA465i.

    Parts on the other side: 12 x 3.5" (SAS/SATA)12 x 3.5" (SAS/SATA) w/ rear 2 x 2.5" (SAS/SATA)12 x 3.5" (SAS/SATA) w/ rear 2 x 2.5" NVMe Direct12 x 3.5" (SAS/SATA) + 4 x 2.5" (SAS/SATA)12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct)

    Source: dell-r760-ism — page 154
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 154View documentSearch this document
    Table 92. 12 x 3.5-inch SAS/SATA with APERC11/12 in Riser 2
    Source: dell-r760-ism — page 157
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 157View documentSearch this document
    Table 95. 12 x 3.5-inch SAS/SATA + 4 x 2.5-inch SAS/SATA with APERC11/12 in Riser 2
  • RequirementThis part can satisfy the requirement of the rule

    Per Dell's cable-routing tables this storage configuration needs one of: PERC H755, PERC H355, HBA355i.

    Parts on the other side: 12 x 3.5" (SAS/SATA) + 4 x EDSFF E3.S (Gen5 x 4 NVMe Direct)

    Source: dell-r760-ism — page 203
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 203View documentSearch this document
    Table 142. 12 x 3.5-inch SAS/SATA + 4 x EDSFF E3.S with APERC11 in Riser 2
    Source: dell-r760-ism — page 261
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 261View documentSearch this document
    Foxconn (PERC Adapter11 H755) 3 1 Foxconn (PERC Adapter11 HBA355i) 3 1 Foxconn (PERC Adapter11 H355) 3 1
  • RequirementThis part can satisfy the requirement of the rule

    Per Dell's cable-routing tables this storage configuration needs one of: HBA355i, PERC H355, PERC H755, PERC H965i.

    Parts on the other side: 8 x 2.5" Universal (SAS/SATA HWRAID + NVMe Direct)

    Source: dell-r760-ism — page 162
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 162View documentSearch this document
    Table 100. 8 x 2.5-inch Universal (SAS/SATA/NVMe) with fPERC (HBA355i, H355, H755)
    Source: dell-r760-ism — page 205
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 205View documentSearch this document
    Table 145. 8 x 2.5-inch Universal (SAS/SATA/NVMe) with fPERC (H965i)
  • RequirementThis part can satisfy the requirement of the rule

    Per Dell's cable-routing tables this storage configuration needs one of: HBA355i, PERC H355, PERC H755, PERC H965i.

    Parts on the other side: 16 x 2.5" (SAS4/SATA) Smart Flow

    Source: dell-r760-ism — page 166
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 166View documentSearch this document
    Table 104. 16 x 2.5-inch SAS/SATA with fPERC (HBA355i, H355, H755)
    Source: dell-r760-ism — page 167
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 167View documentSearch this document
    Table 105. 16 x 2.5-inch SAS/SATA with fPERC (H965i)
  • RequirementThis part can satisfy the requirement of the rule

    Per Dell's cable-routing tables this storage configuration needs one of: HBA355i, PERC H355, PERC H755, PERC H965i.

    Parts on the other side: 16 x 2.5"(SAS4/SATA)+ 8 x 2.5" NVMe Direct

    Source: dell-r760-ism — page 168
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 168View documentSearch this document
    Table 106. 16 x 2.5-inch SAS/SATA + 8 x 2.5-inch NVMe with fPERC (HBA355i, H355, H755)
    Source: dell-r760-ism — page 168
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 168View documentSearch this document
    Table 107. 16 x 2.5-inch SAS/SATA + 8 x 2.5-inch NVMe with fPERC (H965i)
  • RequirementThis part can satisfy the requirement of the rule

    Per Dell's cable-routing tables this storage configuration needs one of: HBA355i, PERC H355, PERC H755, PERC H965i.

    Parts on the other side: 24 x 2.5" (SAS4/SATA) with 8 x Universal slots (SAS/SATA HWRAID + NVMe Direct)

    Source: dell-r760-ism — page 171
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 171View documentSearch this document
    Table 110. 24 x 2.5-inch SAS/SATA with 8 universal (SAS/SATA/NVMe) slots and fPERC (H965i)
    Source: dell-r760-ism — page 188
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 188View documentSearch this document
    Table 127. 24 x 2.5-inch SAS/SATA with 8 universal (SAS/SATA/NVMe) slots and fPERC (HBA355i, H355, H755)
  • RequirementThis part can satisfy the requirement of the rule

    Per Dell's cable-routing tables this storage configuration needs one of: HBA355i, PERC H355, PERC H755, PERC H965i.

    Parts on the other side: 24 x 2.5" (SAS4/SATA)

    Source: dell-r760-ism — page 172
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 172View documentSearch this document
    Table 111. 24 x 2.5-inch SAS/SATA with fPERC (H965i)
    Source: dell-r760-ism — page 181
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 181View documentSearch this document
    Table 120. 24 x 2.5-inch SAS/SATA with fPERC (HBA355i, H355, H755)
  • RequirementThis part can satisfy the requirement of the rule

    Per Dell's cable-routing tables this storage configuration needs one of: HBA355i, PERC H355, PERC H755, PERC H965i.

    Parts on the other side: 24 x 2.5" (SAS4/SATA) + 2 x 2.5" (NVMe Direct)

    Source: dell-r760-ism — page 173
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 173View documentSearch this document
    Table 112. 24 x 2.5-inch SAS/SATA + 2 x 2.5-inch NVMe with fPERC (H965i)
    Source: dell-r760-ism — page 182
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 182View documentSearch this document
    Table 121. 24 x 2.5-inch SAS/SATA + 2 x 2.5-inch NVMe with fPERC (HBA355i, H355, H755)
  • RequirementThis part can satisfy the requirement of the rule

    Per Dell's cable-routing tables this storage configuration needs one of: HBA355i, PERC H355, PERC H755, PERC H965i.

    Parts on the other side: 24 x 2.5"(SAS4/SATA) + 2 x 2.5" (SAS/SATA)

    Source: dell-r760-ism — page 174
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 174View documentSearch this document
    Table 113. 24 x 2.5-inch SAS/SATA + 2 x 2.5-inch SAS/SATA with fPERC (H965i)
    Source: dell-r760-ism — page 183
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 183View documentSearch this document
    Table 122. 24 x 2.5-inch SAS/SATA + 2 x 2.5-inch SAS/SATA with fPERC (HBA355i, H355, H755)
  • RequirementThis part can satisfy the requirement of the rule

    Per Dell's cable-routing tables this storage configuration needs one of: HBA355i, PERC H355, PERC H755, PERC H965i.

    Parts on the other side: 24 x 2.5"(SAS4/SATA) + 4 x 2.5" (SAS/SATA)

    Source: dell-r760-ism — page 175
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 175View documentSearch this document
    Table 114. 24 x 2.5-inch SAS/SATA + 4 x 2.5-inch SAS/SATA with fPERC (H965i)
    Source: dell-r760-ism — page 184
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 184View documentSearch this document
    Table 123. 24 x 2.5-inch SAS/SATA + 4 x 2.5-inch SAS/SATA with fPERC (HBA355i, H355, H755)
  • RequirementThis part can satisfy the requirement of the rule

    Per Dell's cable-routing tables this storage configuration needs one of: HBA355i, PERC H355, PERC H755, PERC H965i.

    Parts on the other side: 24 x 2.5" (SAS4/SATA) + 4 x 2.5" (NVMe Direct)

    Source: dell-r760-ism — page 176
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 176View documentSearch this document
    Table 115. 24 x 2.5-inch SAS/SATA + 4 x 2.5-inch NVMe with fPERC (H965i)
    Source: dell-r760-ism — page 185
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 185View documentSearch this document
    Table 124. 24 x 2.5-inch SAS/SATA + 4 x 2.5-inch NVMe with fPERC (HBA355i, H355, H755)
  • RequirementThis part can satisfy the requirement of the rule

    Per Dell's cable-routing tables this storage configuration needs one of: HBA355i.

    Parts on the other side: 24 x 2.5" (SAS4/SATA) with 4 x Universal slots (SAS/SATA HWRAID + NVMe Direct) + 4 x 2.5" (SAS4/SATA)

    Source: dell-r760-ism — page 189
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 189View documentSearch this document
    Table 128. 24 x 2.5-inch SAS/SATA with 4 universal (SAS/SATA/NVMe) slots+ 4 x 2.5-inch SAS/SATA with fPERC (HBA355i)
  • RequirementThis part can satisfy the requirement of the rule

    Per Dell's cable-routing tables this storage configuration needs one of: HBA355i, PERC H355, PERC H755, PERC H965i.

    Parts on the other side: 24 x 2.5 inches (SAS4/SATA) + 4 x EDSFF E3.S (Gen5 x 4 NVMe Direct)

    Source: dell-r760-ism — page 203
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 203View documentSearch this document
    Table 143. 24 x 2.5-inch SAS/SATA + 4 x EDSFF E3.S with fPERC (HBA355i, H355, H755)
    Source: dell-r760-ism — page 204
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 204View documentSearch this document
    Table 144. 24 x 2.5-inch SAS/SATA + 4 x EDSFF E3.S with fPERC (H965i)
  • No mixingThe rule limits this part

    16 x 2.5-inch NVMe RAID: Dell's cable-routing tables show only a matching pair (two H755N or two H965i); a mixed H755N + H965i pair is not documented.

    Source: dell-r760-ism — page 163
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 163View documentSearch this document
    Table 101. 16 x 2.5-inch NVMe RAID with fPERC (H755N)
    Source: dell-r760-ism — page 165
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 165View documentSearch this document
    Table 103. 16 x 2.5-inch NVMe RAID with fPERC (H965i)
  • Maximum quantityThe rule limits this part

    At most two internal storage controllers: Dell's cable-routing configurations use at most two (dual-controller configurations).

    Source: dell-r760-ism — page 177
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 177View documentSearch this document
    Table 116. 24 x 2.5-inch SAS/SATA dual controller with fPERC (H965i) and APERC in Riser 2
    Source: dell-r760-ism — page 199
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 199View documentSearch this document
    Table 138. 16 x EDSFF E3.S NVMe with dual fPERC (H965i)
  • Maximum quantityThe rule limits this part

    Dell's cable-routing tables for this storage configuration route one front PERC (fPERC) only: at most one internal storage controller (two only on the dual-controller and 16 x 2.5-inch NVMe RAID configurations).

    Source: dell-r760-ism — page 181
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 181View documentSearch this document
    Table 120. 24 x 2.5-inch SAS/SATA with fPERC (HBA355i, H355, H755)
    Source: dell-r760-ism — page 172
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 172View documentSearch this document
    Table 111. 24 x 2.5-inch SAS/SATA with fPERC (H965i)
  • IncompatibilityThis part is one side of an incompatibility

    Riser configuration 8 supports the PERC Adapter only, while this storage configuration's cable tables use front PERCs (fPERC) only.

    Parts on the other side: R1B+R2A

    Source: dell-r760-tg — page 34
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 34View documentSearch this document
    Table 14. PCIe Riser Configurations Config No. Riser configuration No. of Processors PERC type supported Rear storage possible
    Source: dell-r760-tg — page 35
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 35View documentSearch this document
    8 R1B+R2A 1 PERC Adapter No
  • Maximum quantityThe rule limits this part

    Riser configuration 8 takes the PERC Adapter in slot 3 only: one internal controller at most.

    Source: dell-r760-ism — page 282
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 282View documentSearch this document
    Table 164. Configuration 8: R1B+R2A
    Source: dell-r760-ism — page 282
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 282View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    These cards are not listed in the card table of riser configuration 11 (R1 Paddle + R2A + R3B + R4 Paddle) in Dell's ISM and are not supported with it.

    Source: dell-r760-ism — page 291
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 291View documentSearch this document
    Table 168. Configuration 11: R1 paddle+R2A+R3B+R4 paddle
    Source: dell-r760-ism — page 291
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 291View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    With the selected riser configuration Dell's card tables allow at most 1 x HBA355i.

    Source: dell-r760-ism — page 260
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 260View documentSearch this document
    Foxconn (Front PERC11 HBA355i) Integrated slot 1
    Source: dell-r760-ism — page 282
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 282View documentSearch this document
    Foxconn (PERC Adapter11 HBA355i) 3 1
  • RequirementThis part is the condition of the rule

    The allowed number and position of storage controllers (front PERC / PERC Adapter) depend on the riser configuration: select it (or configuration 0 'NO RSR').

    Source: dell-r760-tg — page 34
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 34View documentSearch this document
    Table 14. PCIe Riser Configurations Config No. Riser configuration No. of Processors PERC type supported Rear storage possible
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
  • Maximum quantityThe rule limits this part

    12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 8, 10-1, 10-2 slot cards + adapter <= 3.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    Front + adapter dual-controller base: with riser configuration 8, 10-1, 10-2 slot cards + internal controllers <= 4 (3 slots + the front PERC's integrated slot).

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 6, 9, 11 slot cards + adapter <= 4.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    Front + adapter dual-controller base: with riser configuration 6, 9, 11 slot cards + internal controllers <= 5 (4 slots + the front PERC's integrated slot).

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 3-1, 3-2, 4-1, 5-1, 5-2, 7/12 slot cards + adapter <= 6.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    Front + adapter dual-controller base: with riser configuration 3-1, 3-2, 4-1, 5-1, 5-2, 7/12 slot cards + internal controllers <= 7 (6 slots + the front PERC's integrated slot).

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 1, 2 slot cards + adapter <= 8.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    Front + adapter dual-controller base: with riser configuration 1, 2 slot cards + internal controllers <= 9 (8 slots + the front PERC's integrated slot).

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor

Verification and sources

Verified against this option's row in Dell's official documents; Dell publishes no part number for it - the orderable SKU and price come from a Dell quote.

Document row: dell-r760-ism — page 41
Dell PowerEdge R760 Installation and Service Manual
“dell-r760-ism” — page 41View documentSearch this document
HBA355i