Related rules (5)
- IncompatibilityThe rule applies only when this part is selected
With 2.5-inch drives the documented range of the 2U HPR heat sink is 165 W-350 W.
Parts on the other side: 2U HPR HSK
Source: dell-r760-tg — page 72
Dell PowerEdge R760 Technical Guide2U HPR HSK 125 W–250 W (supports 3.5-inch drives and non-GPU configuration) 165 W–350 W (supports 2.5-inch drives and non-GPU configuration)
- RequirementThe rule applies only when this part is selected
GPU configurations with 24 front 2.5-inch bays (24 x 2.5 SAS, 16 SAS + 8 NVMe, 24 x 2.5 NVMe): 350 W processors are 'Required DLC' in Dell's GPU thermal matrices - one DLC module per processor.
Source: dell-r760-tg — page 78
Dell PowerEdge R760 Technical GuideTable 43. Thermal restriction matrix for GPU configurations
Source: dell-r760-tg — page 79
Dell PowerEdge R760 Technical Guide24 x 2.5- inch SAS 16 x 2.5- inch SAS + 8 x 2.5- inch NVMe 24 x 2.5- inch NVMe
- RequirementThis part is the condition of the rule
Per Dell's cable-routing tables this storage configuration needs one of: HBA355i, PERC H355, PERC H755, PERC H965i.
Parts on the other side: HBA355iPERC H355PERC H755PERC H965i
Source: dell-r760-ism — page 172
Dell PowerEdge R760 Installation and Service ManualTable 111. 24 x 2.5-inch SAS/SATA with fPERC (H965i)
Source: dell-r760-ism — page 181
Dell PowerEdge R760 Installation and Service ManualTable 120. 24 x 2.5-inch SAS/SATA with fPERC (HBA355i, H355, H755)
- Maximum quantityThe rule applies only when this part is selected
Dell's cable-routing tables for this storage configuration route one front PERC (fPERC) only: at most one internal storage controller (two only on the dual-controller and 16 x 2.5-inch NVMe RAID configurations).
Source: dell-r760-ism — page 181
Dell PowerEdge R760 Installation and Service ManualTable 120. 24 x 2.5-inch SAS/SATA with fPERC (HBA355i, H355, H755)
Source: dell-r760-ism — page 172
Dell PowerEdge R760 Installation and Service ManualTable 111. 24 x 2.5-inch SAS/SATA with fPERC (H965i)
- IncompatibilityThe rule applies only when this part is selected
Riser configuration 8 supports the PERC Adapter only, while this storage configuration's cable tables use front PERCs (fPERC) only.
Parts on the other side: R1B+R2A
Source: dell-r760-tg — page 34
Dell PowerEdge R760 Technical GuideTable 14. PCIe Riser Configurations Config No. Riser configuration No. of Processors PERC type supported Rear storage possible
Source: dell-r760-tg — page 35
Dell PowerEdge R760 Technical Guide8 R1B+R2A 1 PERC Adapter No