Dell PowerEdge R760
step «PCIe riser configuration»Only when ordering CTO (factory)Add to this model's configurationRelated rules (23)
- Maximum quantityThe rule applies only when this part is selected
Riser configurations 8, 9, 10-1 and 10-2 are single-processor configurations.
Source: dell-r760-tg — page 34
Dell PowerEdge R760 Technical GuideTable 14. PCIe Riser Configurations Config No. Riser configuration No. of Processors PERC type supported Rear storage possible
Source: dell-r760-tg — page 35
Dell PowerEdge R760 Technical Guide8 R1B+R2A 1 PERC Adapter No
- IncompatibilityThis part is one side of an incompatibility
Rear storage is possible only with riser configurations 6, 7 and 12.
Parts on the other side: 12 x 3.5" (SAS/SATA) w/ rear 2 x 2.5" (SAS/SATA)12 x 3.5" (SAS/SATA) w/ rear 2 x 2.5" NVMe Direct12 x 3.5" (SAS/SATA) + 4 x 2.5" (SAS/SATA)12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct)12 x 3.5" (SAS/SATA) + 4 x EDSFF E3.S (Gen5 x 4 NVMe Direct)24 x 2.5" (SAS4/SATA) + 2 x 2.5" (NVMe Direct)24 x 2.5"(SAS4/SATA) + 2 x 2.5" (SAS/SATA)24 x 2.5"(SAS4/SATA) + 4 x 2.5" (SAS/SATA)24 x 2.5" (SAS4/SATA) + 4 x 2.5" (NVMe Direct)24 x 2.5" + 2 x 2.5" (SAS4/SATA) - Dual Controller24 x 2.5" (SAS4/SATA) with 4 x Universal slots (SAS/SATA HWRAID + NVMe Direct) + 4 x 2.5" (SAS4/SATA)24 x 2.5 inches (SAS4/SATA) + 4 x EDSFF E3.S (Gen5 x 4 NVMe Direct)
Source: dell-r760-tg — page 34
Dell PowerEdge R760 Technical GuideTable 14. PCIe Riser Configurations Config No. Riser configuration No. of Processors PERC type supported Rear storage possible
Source: dell-r760-tg — page 34
Dell PowerEdge R760 Technical Guide6 R2A+R4Q 2 Front PERC/PERC Adapter Yes
- RequirementThis part can satisfy the requirement of the rule
Double-width (DW) GPUs are supported only on riser configurations 3-2, 5-2 or 10-2.
Parts on the other side: A30A40A16A100 80 GBA800H100L40L40S
Source: dell-r760-ism — page 368
Dell PowerEdge R760 Installation and Service ManualCAUTION: Double Width (DW) GPU only supported on Riser Configurations 3-2, 5-2, or 10-2.
Source: dell-r760-ism — page 370
Dell PowerEdge R760 Installation and Service ManualGPU NVIDIA A30, A40, A16, A100, and A800 FH and FL NVIDIA CPU type 2 x 4 (8-position) 1 each for Riser 1 and Riser 4
- Maximum quantityThe rule applies only when this part is selected
Riser configuration 5-2 supports a DW GPU only in slot 7 and 10-2 only in slot 2: at most one DW GPU with these configurations.
Source: dell-r760-ism — page 368
Dell PowerEdge R760 Installation and Service ManualNOTE: *The configuration 5-2 supports DW GPU only on slot 7 and configuration 10-2 supports DW GPU only on slot 2.
Source: dell-r760-tg — page 34
Dell PowerEdge R760 Technical Guide5-2 R1R+R2A+R3A+R4P (FL) 2 Front PERC/PERC Adapter No
- Maximum quantityThe rule applies only when this part is selected
These cards are not listed in the card table of riser configuration 10-2 (R1P+R2A+R4R (FL)) in Dell's ISM and are not supported with it.
Source: dell-r760-ism — page 288
Dell PowerEdge R760 Installation and Service ManualTable 167. Configuration 10-2: R1P+R2A+R4R (FL)
Source: dell-r760-ism — page 288
Dell PowerEdge R760 Installation and Service ManualCard type Slot priority Maximum number of cards
- Maximum quantityThe rule applies only when this part is selected
Riser configuration 10-2: these GPUs install only in slot(s) 2; at most 1 in total.
Source: dell-r760-ism — page 288
Dell PowerEdge R760 Installation and Service ManualTable 167. Configuration 10-2: R1P+R2A+R4R (FL)
Source: dell-r760-ism — page 288
Dell PowerEdge R760 Installation and Service ManualCard type Slot priority Maximum number of cards
- Maximum quantityThe rule applies only when this part is selected
With the selected riser configuration Dell's card tables allow at most 2 GPU(s).
Source: dell-r760-ism — page 370
Dell PowerEdge R760 Installation and Service ManualNOTE: A maximum of two DW GPUs with power cables or a maximum of six SW GPUs are supported in a system based on riser configuration.
Source: dell-r760-ism — page 283
Dell PowerEdge R760 Installation and Service ManualIntel (GPU ATS-M) 1, 2 2
- Maximum quantityThe rule applies only when this part is selected
With the selected riser configuration Dell's card tables allow at most 1 x 540-BDDR.
Source: dell-r760-ism — page 271
Dell PowerEdge R760 Installation and Service ManualIntel (NIC: 25Gb) 2 1
Source: dell-r760-ism — page 279
Dell PowerEdge R760 Installation and Service ManualIntel (NIC: 25Gb) 7 1
- Maximum quantityThe rule applies only when this part is selected
With the selected riser configuration Dell's card tables allow at most 2 x 540-BDIW.
Source: dell-r760-ism — page 284
Dell PowerEdge R760 Installation and Service ManualIntel (NIC: 1Gb) 1, 2 2
Source: dell-r760-ism — page 288
Dell PowerEdge R760 Installation and Service ManualIntel (NIC: 1Gb) 7, 2 2
- Maximum quantityThe rule applies only when this part is selected
With the selected riser configuration Dell's card tables allow at most 3 x HBA355e.
Source: dell-r760-ism — page 280
Dell PowerEdge R760 Installation and Service ManualFoxconn (HBA355e DIB External Adapter) 7, 3, 6 3
Source: dell-r760-ism — page 284
Dell PowerEdge R760 Installation and Service ManualFoxconn (HBA355e DIB External Adapter) 1, 3, 2 3
- Maximum quantityThe rule applies only when this part is selected
With the selected riser configuration Dell's card tables allow at most 1 x HBA355i.
Source: dell-r760-ism — page 260
Dell PowerEdge R760 Installation and Service ManualFoxconn (Front PERC11 HBA355i) Integrated slot 1
Source: dell-r760-ism — page 282
Dell PowerEdge R760 Installation and Service ManualFoxconn (PERC Adapter11 HBA355i) 3 1
- Maximum quantityThe rule applies only when this part is selected
With the selected riser configuration Dell's card tables allow at most 1 x PERC H355.
Source: dell-r760-ism — page 260
Dell PowerEdge R760 Installation and Service ManualFoxconn (Front PERC11 H355) Integrated slot 1
Source: dell-r760-ism — page 283
Dell PowerEdge R760 Installation and Service ManualFoxconn (PERC Adapter11 H355) 3 1
- Maximum quantityThe rule applies only when this part is selected
With the selected riser configuration Dell's card tables allow at most 1 x PERC H755.
Source: dell-r760-ism — page 260
Dell PowerEdge R760 Installation and Service ManualFoxconn (Front PERC11 H755) Integrated slot 1
Source: dell-r760-ism — page 282
Dell PowerEdge R760 Installation and Service ManualFoxconn (PERC Adapter11 H755) 3 1
- Maximum quantityThe rule applies only when this part is selected
With the selected riser configuration Dell's card tables allow at most 1 x PERC H755N.
Source: dell-r760-ism — page 284
Dell PowerEdge R760 Installation and Service ManualFoxconn (Front PERC11 H755N) Integrated slot 1
Source: dell-r760-ism — page 286
Dell PowerEdge R760 Installation and Service ManualFoxconn (Front PERC11 H755N) Integrated slot 1
- Maximum quantityThe rule applies only when this part is selected
Riser configuration 10-2: per Dell's card tables these cards install only in slot(s) 2 (540-BDDR: the Intel 25Gb row with the lowest maximum, conservative reading); at most 1 in total.
Source: dell-r760-ism — page 288
Dell PowerEdge R760 Installation and Service ManualTable 167. Configuration 10-2: R1P+R2A+R4R (FL)
Source: dell-r760-ism — page 288
Dell PowerEdge R760 Installation and Service ManualCard type Slot priority Maximum number of cards
- RequirementThis part can satisfy the requirement of the rule
GPUs install in riser slots and their maximum depends on the riser configuration: select a riser configuration that supports GPUs.
Source: dell-r760-ism — page 370
Dell PowerEdge R760 Installation and Service ManualNOTE: A maximum of two DW GPUs with power cables or a maximum of six SW GPUs are supported in a system based on riser configuration.
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
- RequirementThis part can satisfy the requirement of the rule
External controllers (PERC H965e / HBA355e) install in a riser PCIe slot: select a riser configuration with slots (configuration 0 has none).
Parts on the other side: PERC H965eHBA355e
Source: dell-r760-ism — page 262
Dell PowerEdge R760 Installation and Service ManualFoxconn (H965e DIB External Adapter) 6, 3 1
Source: dell-r760-ism — page 260
Dell PowerEdge R760 Installation and Service ManualTable 154. Configuration 0: No risers
- RequirementThis part can satisfy the requirement of the rule
PCIe NICs (540-BDIW / 540-BDDR, full height) install in a riser PCIe slot: select a riser configuration with slots (configuration 0 has none).
Parts on the other side: 540-BDDR540-BDIW
Source: dell-r760-tg — page 92
Dell PowerEdge R760 Technical GuideIntel Ethernet i350 Quad Port 1 GbE BASE-T Adapter, PCIe Full Height, V2, FIRMWARE RESTRICTIONS APPLY [540-BDIW]
Source: dell-r760-tg — page 92
Dell PowerEdge R760 Technical GuideIntel E810-XXVDA4 Quad Port 10/25GbE SFP28 Adapter, PCIe Full Height [540-BDDR]
- Maximum quantityThe rule applies only when this part is selected
The selected riser configuration (8, 10-1, 10-2) has 3 PCIe slot(s) (ISM Table 153): GPUs + PCIe NICs + external controllers <= 3.
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule applies only when this part is selected
12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 8, 10-1, 10-2 slot cards + adapter <= 3.
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule applies only when this part is selected
Front + adapter dual-controller base: with riser configuration 8, 10-1, 10-2 slot cards + internal controllers <= 4 (3 slots + the front PERC's integrated slot).
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule applies only when this part is selected
The selected riser configuration (6, 8, 10-1, 10-2, 11) has 2 full-height slot(s) (Table 153): GPUs + full-height PCIe NICs <= 2.
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- RequirementA general rule that covers this part through its attributes
The allowed number and position of storage controllers (front PERC / PERC Adapter) depend on the riser configuration: select it (or configuration 0 'NO RSR').
Parts on the other side: PERC H965iPERC H755PERC H755NPERC H355HBA355iHBA465i
Source: dell-r760-tg — page 34
Dell PowerEdge R760 Technical GuideTable 14. PCIe Riser Configurations Config No. Riser configuration No. of Processors PERC type supported Rear storage possible
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations