Kimia Shop

H100

Graphics card

Dell option (no published part number)

Configuration Rear storage GPU: H100 (Max 2) | No backplane No rear drives HPR GOLD fan with 1U HPR L-Type HSK: 35°C (95°F) | 8 x 2.5- inch NVMe No rear drives: 35°C (95°F) | 16 x 2.5-inch SAS and split NVMe- SAS No rear drives: 35°C (95°F) | 16 x 2.5-inch NVMe or 16 x EDSFF E3.S NVMe No rear drives: 35°C (95°F) | 24 x 2.5- inch SAS No rear drives: 35°C (95°F) | 16 x 2.5- inch SAS + 8 x 2.5- inch NVMe No rear drives: 35°C (95°F) | 24 x 2.5- inch NVMe No rear drives: 35°C (95°F)

Verified in 1 active model(s): Dell PowerEdge R760

Description

GPU / accelerator card

A GPU or PCIe accelerator card that takes heavy parallel processing off the CPU; it comes in single-wide or double-wide form.

It is essential for training and inference of AI models, rendering, VDI and scientific computing.

The processing time of these workloads drops to a fraction of the time on the CPU.

This text is the general explanation of this category of part (not a claim about one specific model).

Compatibility map

The relations of this part with other parts, from the audited QuickSpecs rules and the compatibility graph only (every line with its official source).

H100R1P+R2A+R3B+R4P (FL)R1R+R2A+R3A+R4P (FL)R1P+R2A+R4R (FL)STD HSK2U HPR HSK12 x 3.5" (SAS/SATA)12 x 3.5" (SAS/SATA) w/ rear 2 x 2.5" (SAS/SATA)12 x 3.5" (SAS/SATA) w/ rear 2 x 2.5" NVMe Direct12 x 3.5" (SAS/SATA) + 4 x 2.5" (SAS/SATA)12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct)12 x 3.5" (SAS/SATA) + 4 x EDSFF E3.S (Gen5 x 4 NVMe Direct)24 x 2.5" (SAS4/SATA) + 2 x 2.5" (NVMe Direct)24 x 2.5"(SAS4/SATA) + 2 x 2.5" (SAS/SATA)24 x 2.5"(SAS4/SATA) + 4 x 2.5" (SAS/SATA)

Click a part or a relation line (or press Enter) to pin its explanation and source; Esc releases it. Drag to pan the map or use the arrow keys; zoom with the buttons, the + and − keys or Ctrl with the mouse wheel. 18 more related part(s) were left off the map for legibility; the rule list on this page is more complete.

Hover or click a part or a relation to show its recorded rule and official source.

  • Requires: H100 requires R1P+R2A+R3B+R4P (FL). Double-width (DW) GPUs are supported only on riser configurations 3-2, 5-2 or 10-2.
  • Requires: H100 requires R1P+R2A+R3B+R4P (FL). GPUs install in riser slots and their maximum depends on the riser configuration: select a riser configuration that supports GPUs.
  • Requires: H100 requires R1R+R2A+R3A+R4P (FL). Double-width (DW) GPUs are supported only on riser configurations 3-2, 5-2 or 10-2.
  • Requires: H100 requires R1R+R2A+R3A+R4P (FL). GPUs install in riser slots and their maximum depends on the riser configuration: select a riser configuration that supports GPUs.
  • Requires: H100 requires R1P+R2A+R4R (FL). Double-width (DW) GPUs are supported only on riser configurations 3-2, 5-2 or 10-2.
  • Requires: H100 requires R1P+R2A+R4R (FL). GPUs install in riser slots and their maximum depends on the riser configuration: select a riser configuration that supports GPUs.
  • Incompatible: H100 and STD HSK are incompatible. The STD heat sink is for non-GPU configurations only.
  • Incompatible: 2U HPR HSK and H100 are incompatible. The 2U HPR heat sink is for non-GPU configurations; all GPU cards require the 1U L-type heat sink.
  • Incompatible: 12 x 3.5" (SAS/SATA) and H100 are incompatible. 12 x 3.5-inch and rear-drive configurations do not support a GPU card.
  • Incompatible: 12 x 3.5" (SAS/SATA) w/ rear 2 x 2.5" (SAS/SATA) and H100 are incompatible. 12 x 3.5-inch and rear-drive configurations do not support a GPU card.
  • Incompatible: 12 x 3.5" (SAS/SATA) w/ rear 2 x 2.5" NVMe Direct and H100 are incompatible. 12 x 3.5-inch and rear-drive configurations do not support a GPU card.
  • Incompatible: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (SAS/SATA) and H100 are incompatible. 12 x 3.5-inch and rear-drive configurations do not support a GPU card.
  • Incompatible: 12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct) and H100 are incompatible. 12 x 3.5-inch and rear-drive configurations do not support a GPU card.
  • Incompatible: 12 x 3.5" (SAS/SATA) + 4 x EDSFF E3.S (Gen5 x 4 NVMe Direct) and H100 are incompatible. 12 x 3.5-inch and rear-drive configurations do not support a GPU card.
  • Incompatible: 24 x 2.5" (SAS4/SATA) + 2 x 2.5" (NVMe Direct) and H100 are incompatible. 12 x 3.5-inch and rear-drive configurations do not support a GPU card.
  • Incompatible: 24 x 2.5"(SAS4/SATA) + 2 x 2.5" (SAS/SATA) and H100 are incompatible. 12 x 3.5-inch and rear-drive configurations do not support a GPU card.
  • Incompatible: 24 x 2.5"(SAS4/SATA) + 4 x 2.5" (SAS/SATA) and H100 are incompatible. 12 x 3.5-inch and rear-drive configurations do not support a GPU card.

Active models in which this part is listed

Dell PowerEdge R760

step «GPU»Add to this model's configuration

Related rules (47)

  • RequirementThis part is the condition of the rule

    Double-width (DW) GPUs are supported only on riser configurations 3-2, 5-2 or 10-2.

    Parts on the other side: R1P+R2A+R3B+R4P (FL)R1R+R2A+R3A+R4P (FL)R1P+R2A+R4R (FL)

    Source: dell-r760-ism — page 368
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 368View documentSearch this document
    CAUTION: Double Width (DW) GPU only supported on Riser Configurations 3-2, 5-2, or 10-2.
    Source: dell-r760-ism — page 370
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 370View documentSearch this document
    GPU NVIDIA A30, A40, A16, A100, and A800 FH and FL NVIDIA CPU type 2 x 4 (8-position) 1 each for Riser 1 and Riser 4
  • Maximum quantityThe rule limits this part

    Riser configuration 5-2 supports a DW GPU only in slot 7 and 10-2 only in slot 2: at most one DW GPU with these configurations.

    Source: dell-r760-ism — page 368
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 368View documentSearch this document
    NOTE: *The configuration 5-2 supports DW GPU only on slot 7 and configuration 10-2 supports DW GPU only on slot 2.
    Source: dell-r760-tg — page 34
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 34View documentSearch this document
    5-2 R1R+R2A+R3A+R4P (FL) 2 Front PERC/PERC Adapter No
  • Maximum quantityThe rule limits this part

    A maximum of two DW GPUs is supported.

    Source: dell-r760-ism — page 370
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 370View documentSearch this document
    NOTE: A maximum of two DW GPUs with power cables or a maximum of six SW GPUs are supported in a system based on riser configuration.
    Source: dell-r760-tg — page 9
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 9View documentSearch this document
    GPU Options Up to two double wide 350 W, or six single wide 75 W accelerators
  • WarningThe rule applies only when this part is selected

    Dell documents 'two DW GPUs or six SW GPUs'; mixing DW and SW GPUs is not documented.

    Source: dell-r760-ism — page 370
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 370View documentSearch this document
    NOTE: A maximum of two DW GPUs with power cables or a maximum of six SW GPUs are supported in a system based on riser configuration.
    Source: dell-r760-tg — page 9
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 9View documentSearch this document
    GPU Options Up to two double wide 350 W, or six single wide 75 W accelerators
  • Maximum quantityThe rule limits this part

    Per the GPU thermal table these GPUs are 'Max 2'.

    Source: dell-r760-tg — page 86
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 86View documentSearch this document
    A40 (Max 2) 35°C (95°F)
    Source: dell-r760-tg — page 86
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 86View documentSearch this document
    Intel PVC (Max 2)
  • Maximum quantityThe rule limits this part

    These cards are not listed in the card table of riser configuration 0 (NO RSR) in Dell's ISM and are not supported with it.

    Source: dell-r760-ism — page 260
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 260View documentSearch this document
    Table 154. Configuration 0: No risers
    Source: dell-r760-ism — page 260
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 260View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    These cards are not listed in the card table of riser configuration 1 (R1B+R2A+R3B+R4B) in Dell's ISM and are not supported with it.

    Source: dell-r760-ism — page 260
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 260View documentSearch this document
    Table 155. Configuration 1: R1B+R2A+R3B+R4B
    Source: dell-r760-ism — page 260
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 260View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    These cards are not listed in the card table of riser configuration 2 (R1Q+R2A+R3B+R4Q) in Dell's ISM and are not supported with it.

    Source: dell-r760-ism — page 262
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 262View documentSearch this document
    Table 156. Configuration 2: R1Q+R2A+R3B+R4Q
    Source: dell-r760-ism — page 262
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 262View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    These cards are not listed in the card table of riser configuration 3-1 (R1P+R2A+R3B+R4P (HL)) in Dell's ISM and are not supported with it.

    Source: dell-r760-ism — page 264
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 264View documentSearch this document
    Table 157. Configuration 3-1: R1P+R2A+R3B+R4P (HL)
    Source: dell-r760-ism — page 264
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 264View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    Riser configuration 3-2: these GPUs install only in slot(s) 7, 2; at most 2 in total.

    Source: dell-r760-ism — page 267
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 267View documentSearch this document
    Table 158. Configuration 3-2: R1P+R2A+R3B+R4P (FL)
    Source: dell-r760-ism — page 267
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 267View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    These cards are not listed in the card table of riser configuration 4-1 (R1P+R2A+R3B+R4R (HL)) in Dell's ISM and are not supported with it.

    Source: dell-r760-ism — page 270
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 270View documentSearch this document
    Table 159. Configuration 4-1: R1P+R2A+R3B+R4R (HL)
    Source: dell-r760-ism — page 270
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 270View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    These cards are not listed in the card table of riser configuration 5-1 (R1R+R2A+R3A+R4P (HL)) in Dell's ISM and are not supported with it.

    Source: dell-r760-ism — page 272
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 272View documentSearch this document
    Table 160. Configuration 5-1: R1R+R2A+R3A+R4P (HL)
    Source: dell-r760-ism — page 272
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 272View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    Riser configuration 5-2: these GPUs install only in slot(s) 7; at most 1 in total.

    Source: dell-r760-ism — page 275
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 275View documentSearch this document
    Table 161. Configuration 5-2: R1R+R2A+R3A+R4P (FL)
    Source: dell-r760-ism — page 275
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 275View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    These cards are not listed in the card table of riser configuration 6 (R2A+R4Q) in Dell's ISM and are not supported with it.

    Source: dell-r760-ism — page 278
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 278View documentSearch this document
    Table 162. Configuration 6: R2A+R4Q
    Source: dell-r760-ism — page 278
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 278View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    These cards are not listed in the card table of riser configuration 7/12 (R1Q+R2A+R4Q) in Dell's ISM and are not supported with it.

    Source: dell-r760-ism — page 280
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 280View documentSearch this document
    Table 163. Configuration 7: R1Q+R2A+R4Q
    Source: dell-r760-ism — page 280
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 280View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    These cards are not listed in the card table of riser configuration 8 (R1B+R2A) in Dell's ISM and are not supported with it.

    Source: dell-r760-ism — page 282
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 282View documentSearch this document
    Table 164. Configuration 8: R1B+R2A
    Source: dell-r760-ism — page 282
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 282View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    These cards are not listed in the card table of riser configuration 9 (R1Q+R2A+R4R) in Dell's ISM and are not supported with it.

    Source: dell-r760-ism — page 284
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 284View documentSearch this document
    Table 165. Configuration 9: R1Q+R2A+R4R
    Source: dell-r760-ism — page 284
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 284View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    These cards are not listed in the card table of riser configuration 10-1 (R1P+R2A+R4R (HL)) in Dell's ISM and are not supported with it.

    Source: dell-r760-ism — page 286
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 286View documentSearch this document
    Table 166. Configuration 10-1: R1P+R2A+R4R (HL)
    Source: dell-r760-ism — page 286
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 286View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    Riser configuration 10-2: these GPUs install only in slot(s) 2; at most 1 in total.

    Source: dell-r760-ism — page 288
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 288View documentSearch this document
    Table 167. Configuration 10-2: R1P+R2A+R4R (FL)
    Source: dell-r760-ism — page 288
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 288View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    These cards are not listed in the card table of riser configuration 11 (R1 Paddle + R2A + R3B + R4 Paddle) in Dell's ISM and are not supported with it.

    Source: dell-r760-ism — page 291
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 291View documentSearch this document
    Table 168. Configuration 11: R1 paddle+R2A+R3B+R4 paddle
    Source: dell-r760-ism — page 291
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 291View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    Riser configuration 3-2: per Dell's card tables these cards install only in slot(s) 7, 2 (540-BDDR: the Intel 25Gb row with the lowest maximum, conservative reading); at most 2 in total.

    Source: dell-r760-ism — page 267
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 267View documentSearch this document
    Table 158. Configuration 3-2: R1P+R2A+R3B+R4P (FL)
    Source: dell-r760-ism — page 267
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 267View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    Riser configuration 10-2: per Dell's card tables these cards install only in slot(s) 2 (540-BDDR: the Intel 25Gb row with the lowest maximum, conservative reading); at most 1 in total.

    Source: dell-r760-ism — page 288
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 288View documentSearch this document
    Table 167. Configuration 10-2: R1P+R2A+R4R (FL)
    Source: dell-r760-ism — page 288
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 288View documentSearch this document
    Card type Slot priority Maximum number of cards
  • Maximum quantityThe rule limits this part

    The selected riser configuration (0) has 0 PCIe slot(s) (ISM Table 153): GPUs + PCIe NICs + external controllers <= 0.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    The selected riser configuration (8, 10-1, 10-2) has 3 PCIe slot(s) (ISM Table 153): GPUs + PCIe NICs + external controllers <= 3.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 8, 10-1, 10-2 slot cards + adapter <= 3.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    Front + adapter dual-controller base: with riser configuration 8, 10-1, 10-2 slot cards + internal controllers <= 4 (3 slots + the front PERC's integrated slot).

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    The selected riser configuration (6, 9, 11) has 4 PCIe slot(s) (ISM Table 153): GPUs + PCIe NICs + external controllers <= 4.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 6, 9, 11 slot cards + adapter <= 4.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    Front + adapter dual-controller base: with riser configuration 6, 9, 11 slot cards + internal controllers <= 5 (4 slots + the front PERC's integrated slot).

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    The selected riser configuration (3-1, 3-2, 4-1, 5-1, 5-2, 7/12) has 6 PCIe slot(s) (ISM Table 153): GPUs + PCIe NICs + external controllers <= 6.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 3-1, 3-2, 4-1, 5-1, 5-2, 7/12 slot cards + adapter <= 6.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    Front + adapter dual-controller base: with riser configuration 3-1, 3-2, 4-1, 5-1, 5-2, 7/12 slot cards + internal controllers <= 7 (6 slots + the front PERC's integrated slot).

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    The selected riser configuration (1, 2) has 8 PCIe slot(s) (ISM Table 153): GPUs + PCIe NICs + external controllers <= 8.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 1, 2 slot cards + adapter <= 8.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    Front + adapter dual-controller base: with riser configuration 1, 2 slot cards + internal controllers <= 9 (8 slots + the front PERC's integrated slot).

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    The selected riser configuration (6, 8, 10-1, 10-2, 11) has 2 full-height slot(s) (Table 153): GPUs + full-height PCIe NICs <= 2.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    The selected riser configuration (9) has 3 full-height slot(s) (Table 153): GPUs + full-height PCIe NICs <= 3.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    The selected riser configuration (3-1, 3-2, 4-1, 5-1, 5-2, 7/12) has 4 full-height slot(s) (Table 153): GPUs + full-height PCIe NICs <= 4.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • Maximum quantityThe rule limits this part

    The selected riser configuration (1, 2) has 6 full-height slot(s) (Table 153): GPUs + full-height PCIe NICs <= 6.

    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Configurations Expansion card risers PCIe Slots Form factor Controlling processor
  • IncompatibilityA general rule that covers this part through its attributes

    The STD heat sink is for non-GPU configurations only.

    Parts on the other side: STD HSK

    Source: dell-r760-tg — page 72
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 72View documentSearch this document
    STD HSK ≤ 165 W (supports only 2.5-inch drives and non-GPU configuration)
    Source: dell-r760-tg — page 72
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 72View documentSearch this document
    L-type HSK Supports all GPU/FPGA configurations NOTE: All GPU/FGPA cards require 1U L-type HSK and GPU shroud.
  • IncompatibilityA general rule that covers this part through its attributes

    The 2U HPR heat sink is for non-GPU configurations; all GPU cards require the 1U L-type heat sink.

    Parts on the other side: 2U HPR HSK

    Source: dell-r760-tg — page 72
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 72View documentSearch this document
    2U HPR HSK 125 W–250 W (supports 3.5-inch drives and non-GPU configuration) 165 W–350 W (supports 2.5-inch drives and non-GPU configuration)
    Source: dell-r760-tg — page 72
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 72View documentSearch this document
    L-type HSK Supports all GPU/FPGA configurations NOTE: All GPU/FGPA cards require 1U L-type HSK and GPU shroud.
  • RequirementA general rule that covers this part through its attributes

    All GPU cards require the 1U L-type heat sink and the GPU shroud (one per processor); where the GPU thermal matrix says 'Required DLC' the DLC module is used instead of the L-type heat sink.

    Parts on the other side: L-type HSKDLC

    Source: dell-r760-tg — page 72
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 72View documentSearch this document
    L-type HSK Supports all GPU/FPGA configurations NOTE: All GPU/FGPA cards require 1U L-type HSK and GPU shroud.
    Source: dell-r760-ism — page 368
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 368View documentSearch this document
    Heat sinks L-type heat sink for processor 1 and processor 2 RC 3-2, 5-2: 2 RC 10-2: 1
  • RequirementA general rule that covers this part through its attributes

    The L-type heat sink is for GPU/FPGA configurations; non-GPU configurations use the STD or 2U HPR heat sink per Dell's heat sink matrix.

    Parts on the other side: L-type HSK

    Source: dell-r760-tg — page 72
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 72View documentSearch this document
    L-type HSK Supports all GPU/FPGA configurations NOTE: All GPU/FGPA cards require 1U L-type HSK and GPU shroud.
    Source: dell-r760-tg — page 72
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 72View documentSearch this document
    STD HSK ≤ 165 W (supports only 2.5-inch drives and non-GPU configuration)
  • IncompatibilityA general rule that covers this part through its attributes

    12 x 3.5-inch and rear-drive configurations do not support a GPU card.

    Parts on the other side: 12 x 3.5" (SAS/SATA)12 x 3.5" (SAS/SATA) w/ rear 2 x 2.5" (SAS/SATA)12 x 3.5" (SAS/SATA) w/ rear 2 x 2.5" NVMe Direct12 x 3.5" (SAS/SATA) + 4 x 2.5" (SAS/SATA)12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct)12 x 3.5" (SAS/SATA) + 4 x EDSFF E3.S (Gen5 x 4 NVMe Direct)24 x 2.5" (SAS4/SATA) + 2 x 2.5" (NVMe Direct)24 x 2.5"(SAS4/SATA) + 2 x 2.5" (SAS/SATA)24 x 2.5"(SAS4/SATA) + 4 x 2.5" (SAS/SATA)24 x 2.5" (SAS4/SATA) + 4 x 2.5" (NVMe Direct)24 x 2.5" + 2 x 2.5" (SAS4/SATA) - Dual Controller24 x 2.5" (SAS4/SATA) with 4 x Universal slots (SAS/SATA HWRAID + NVMe Direct) + 4 x 2.5" (SAS4/SATA)

    Source: dell-r760-ism — page 369
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 369View documentSearch this document
    NOTE: 12 x 3.5-inch and rear drive configuration systems do not support a GPU card.
  • RequirementA general rule that covers this part through its attributes

    GPU configurations support only HPR Gold fans (six, per the GPU kit).

    Parts on the other side: HPR Gold

    Source: dell-r760-tg — page 80
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 80View documentSearch this document
    NOTE: GPU configuration supports only High performance Gold (HPR Gold) fan.
    Source: dell-r760-ism — page 368
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 368View documentSearch this document
    Fans HPR GOLD fan 6
  • IncompatibilityA general rule that covers this part through its attributes

    GPU configurations support only HPR Gold fans.

    Parts on the other side: STDHPR Silver

    Source: dell-r760-tg — page 80
    Dell PowerEdge R760 Technical Guide
    “dell-r760-tg” — page 80View documentSearch this document
    NOTE: GPU configuration supports only High performance Gold (HPR Gold) fan.
  • RequirementA general rule that covers this part through its attributes

    GPUs install in riser slots and their maximum depends on the riser configuration: select a riser configuration that supports GPUs.

    Parts on the other side: R1B+R2A+R3B+R4BR1Q+R2A+R3B+R4QR1P+R2A+R3B+R4P (HL)R1P+R2A+R3B+R4P (FL)R1P+R2A+R3B+R4R (HL)R1R+R2A+R3A+R4P (HL)R1R+R2A+R3A+R4P (FL)R1B+R2AR1Q+R2A+R4RR1P+R2A+R4R (HL)R1P+R2A+R4R (FL)R1 Paddle + R2A + R3B + R4 Paddle

    Source: dell-r760-ism — page 370
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 370View documentSearch this document
    NOTE: A maximum of two DW GPUs with power cables or a maximum of six SW GPUs are supported in a system based on riser configuration.
    Source: dell-r760-ism — page 256
    Dell PowerEdge R760 Installation and Service Manual
    “dell-r760-ism” — page 256View documentSearch this document
    Table 153. Expansion card riser configurations

Verification and sources

Verified against this option's row in Dell's official documents; Dell publishes no part number for it - the orderable SKU and price come from a Dell quote.

Document row: dell-r760-tg — page 86
Dell PowerEdge R760 Technical Guide
“dell-r760-tg” — page 86View documentSearch this document
H100 (Max 2) 35°C (95°F) 35°C (95°F) 35°C (95°F) 35°C (95°F) 35°C (95°F) 35°C (95°F) 35°C (95°F)

This page contains only the audited data of the official vendor documents (HPE, Lenovo, Dell) for the active models. Price and availability are given through the quote request in the configurator.