Related rules (9)
- RequirementThis part can satisfy the requirement of the rule
9480, 9470, 8470Q and 6458Q are supported only in a liquid cooling (DLC) configuration.
Parts on the other side: 948094708470Q6458Q
Source: dell-r760-tg — page 18
Dell PowerEdge R760 Technical GuideNOTE: 9480, 9470, 8470Q and 6458Q are supported only in liquid cooling configuration.
Source: dell-r760-tg — page 73
Dell PowerEdge R760 Technical GuideDLC Direct Liquid Cooling
- RequirementThis part can satisfy the requirement of the rule
All GPU cards require the 1U L-type heat sink and the GPU shroud (one per processor); where the GPU thermal matrix says 'Required DLC' the DLC module is used instead of the L-type heat sink.
Source: dell-r760-tg — page 72
Dell PowerEdge R760 Technical GuideL-type HSK Supports all GPU/FPGA configurations NOTE: All GPU/FGPA cards require 1U L-type HSK and GPU shroud.
Source: dell-r760-ism — page 368
Dell PowerEdge R760 Installation and Service ManualHeat sinks L-type heat sink for processor 1 and processor 2 RC 3-2, 5-2: 2 RC 10-2: 1
- RequirementThis part can satisfy the requirement of the rule
GPU configurations with 24 front 2.5-inch bays (24 x 2.5 SAS, 16 SAS + 8 NVMe, 24 x 2.5 NVMe): 350 W processors are 'Required DLC' in Dell's GPU thermal matrices - one DLC module per processor.
Source: dell-r760-tg — page 78
Dell PowerEdge R760 Technical GuideTable 43. Thermal restriction matrix for GPU configurations
Source: dell-r760-tg — page 79
Dell PowerEdge R760 Technical Guide24 x 2.5- inch SAS 16 x 2.5- inch SAS + 8 x 2.5- inch NVMe 24 x 2.5- inch NVMe
- RequirementThis part can satisfy the requirement of the rule
Select one heat sink (STD, 2U HPR or L-type per the heat sink matrix) or the DLC module per processor.
Source: dell-r760-tg — page 72
Dell PowerEdge R760 Technical GuideTable 38. Processor and heat sink matrix Heat sink Processor TDP
Source: dell-r760-ism — page 368
Dell PowerEdge R760 Installation and Service ManualHeat sinks L-type heat sink for processor 1 and processor 2 RC 3-2, 5-2: 2 RC 10-2: 1
- Maximum quantityThe rule limits this part
No more heat sinks / DLC modules than processors (one per processor).
Source: dell-r760-tg — page 72
Dell PowerEdge R760 Technical GuideTable 38. Processor and heat sink matrix Heat sink Processor TDP
Source: dell-r760-ism — page 368
Dell PowerEdge R760 Installation and Service ManualHeat sinks L-type heat sink for processor 1 and processor 2 RC 3-2, 5-2: 2 RC 10-2: 1
- IncompatibilityThis part is one side of an incompatibility
Dell documents air cooling and liquid cooling (DLC) as separate whole-system configurations; a DLC module on one processor with an air heat sink (STD, 2U HPR or L-type) on the other is not documented.
Parts on the other side: STD HSK2U HPR HSKL-type HSK
Source: dell-r760-ism — page 39
Dell PowerEdge R760 Installation and Service ManualNOTE: See the Thermal restriction matrix for required fan support with air cooled and DLC configurations.
Source: dell-r760-tg — page 18
Dell PowerEdge R760 Technical GuideNOTE: 9480, 9470, 8470Q and 6458Q are supported only in liquid cooling configuration.
- RequirementThis part can satisfy the requirement of the rule
12 x 3.5-inch configurations (with or without rear drives): processors of 270 W and above are 'Required DLC' in Dell's thermal matrices - one DLC module per processor.
Source: dell-r760-tg — page 73
Dell PowerEdge R760 Technical GuideTable 40. Thermal restriction matrix for air cooled configuration
Source: dell-r760-tg — page 74
Dell PowerEdge R760 Technical Guide6444Y 270 W² 32 75 HPR SLVR HPR SLV R HPR SLVR HPR SLVR HP R SL VR HPR SLVR HPR SLVR HPR GOL D Req uire d DLC Require d DLC 35°C (95°F)
- WarningThe rule applies only when this part is selected
DLC is a rack solution and requires rack manifolds and a cooling distribution unit (CDU) to operate.
Source: dell-r760-tg — page 7
Dell PowerEdge R760 Technical GuideNOTE: DLC is a rack solution and requires rack manifolds and a cooling distribution unit (CDU) to operate.
- IncompatibilityThis part is one side of an incompatibility
The CMA is not supported in the Direct Liquid Cooling configuration.
Parts on the other side: CMA
Source: dell-r760-tg — page 46
Dell PowerEdge R760 Technical GuideNOTE: CMA is not supported in the Direct Liquid Cooling configuration.
Source: dell-r760-ism — page 365
Dell PowerEdge R760 Installation and Service ManualNOTE: CMA is not supported in Direct Liquid Cooling configuration.