Related rules (5)
- RequirementThis part can satisfy the requirement of the rule
All GPU cards require the 1U L-type heat sink and the GPU shroud (one per processor); where the GPU thermal matrix says 'Required DLC' the DLC module is used instead of the L-type heat sink.
Source: dell-r760-tg — page 72
Dell PowerEdge R760 Technical GuideL-type HSK Supports all GPU/FPGA configurations NOTE: All GPU/FGPA cards require 1U L-type HSK and GPU shroud.
Source: dell-r760-ism — page 368
Dell PowerEdge R760 Installation and Service ManualHeat sinks L-type heat sink for processor 1 and processor 2 RC 3-2, 5-2: 2 RC 10-2: 1
- RequirementThis part can satisfy the requirement of the rule
Select one heat sink (STD, 2U HPR or L-type per the heat sink matrix) or the DLC module per processor.
Source: dell-r760-tg — page 72
Dell PowerEdge R760 Technical GuideTable 38. Processor and heat sink matrix Heat sink Processor TDP
Source: dell-r760-ism — page 368
Dell PowerEdge R760 Installation and Service ManualHeat sinks L-type heat sink for processor 1 and processor 2 RC 3-2, 5-2: 2 RC 10-2: 1
- RequirementThis part is the condition of the rule
The L-type heat sink is for GPU/FPGA configurations; non-GPU configurations use the STD or 2U HPR heat sink per Dell's heat sink matrix.
Source: dell-r760-tg — page 72
Dell PowerEdge R760 Technical GuideL-type HSK Supports all GPU/FPGA configurations NOTE: All GPU/FGPA cards require 1U L-type HSK and GPU shroud.
Source: dell-r760-tg — page 72
Dell PowerEdge R760 Technical GuideSTD HSK ≤ 165 W (supports only 2.5-inch drives and non-GPU configuration)
- Maximum quantityThe rule limits this part
No more heat sinks / DLC modules than processors (one per processor).
Source: dell-r760-tg — page 72
Dell PowerEdge R760 Technical GuideTable 38. Processor and heat sink matrix Heat sink Processor TDP
Source: dell-r760-ism — page 368
Dell PowerEdge R760 Installation and Service ManualHeat sinks L-type heat sink for processor 1 and processor 2 RC 3-2, 5-2: 2 RC 10-2: 1
- IncompatibilityThis part is one side of an incompatibility
Dell documents air cooling and liquid cooling (DLC) as separate whole-system configurations; a DLC module on one processor with an air heat sink (STD, 2U HPR or L-type) on the other is not documented.
Parts on the other side: DLC
Source: dell-r760-ism — page 39
Dell PowerEdge R760 Installation and Service ManualNOTE: See the Thermal restriction matrix for required fan support with air cooled and DLC configurations.
Source: dell-r760-tg — page 18
Dell PowerEdge R760 Technical GuideNOTE: 9480, 9470, 8470Q and 6458Q are supported only in liquid cooling configuration.