Related rules (6)
- WarningThe rule applies only when this part is selected
Dell states 6400/5600 MT/s RDIMMs are applicable for 5th Gen processors; the only rows of 'Supported DIMMs' are 6400 MT/s, the 4800 MT/s RDIMMs for 4th Gen appear only in the memory matrix - confirm memory for a 4th Gen processor.
Source: dell-r760-tg — page 20
Dell PowerEdge R760 Technical GuideNOTE: 6400/5600 MT/s RDIMMs are applicable for 5th Gen Intel® Xeon® Scalable Processors.
Source: dell-r760-tg — page 19
Dell PowerEdge R760 Technical GuideTable 6. Supported DIMMs
- WarningThe rule applies only when this part is selected
This option needs expert review (see the item note).
Source: dell-r760-ism — page 39
Dell PowerEdge R760 Installation and Service ManualNOTE: See the Thermal restriction matrix for required fan support with air cooled and DLC configurations.
Source: dell-r760-tg — page 20
Dell PowerEdge R760 Technical GuideNOTE: 6400/5600 MT/s RDIMMs are applicable for 5th Gen Intel® Xeon® Scalable Processors.
- IncompatibilityA general rule that covers this part through its attributes
The STD heat sink supports processors up to 165 W only.
Parts on the other side: STD HSK
Source: dell-r760-tg — page 72
Dell PowerEdge R760 Technical GuideSTD HSK ≤ 165 W (supports only 2.5-inch drives and non-GPU configuration)
- RequirementA general rule that covers this part through its attributes
Select one heat sink (STD, 2U HPR or L-type per the heat sink matrix) or the DLC module per processor.
Parts on the other side: STD HSK2U HPR HSKL-type HSKDLC
Source: dell-r760-tg — page 72
Dell PowerEdge R760 Technical GuideTable 38. Processor and heat sink matrix Heat sink Processor TDP
Source: dell-r760-ism — page 368
Dell PowerEdge R760 Installation and Service ManualHeat sinks L-type heat sink for processor 1 and processor 2 RC 3-2, 5-2: 2 RC 10-2: 1
- RequirementA general rule that covers this part through its attributes
Cooling fans must be selected; the fan type depends on processor TDP, storage, rear drives and GPU per Dell's thermal matrix (expert review).
Source: dell-r760-ism — page 38
Dell PowerEdge R760 Installation and Service ManualThe PowerEdge R760 requires various cooling components that are based on processor TDP, storage modules, rear drives, and GPU to maintain optimum thermal performance.
Source: dell-r760-ism — page 39
Dell PowerEdge R760 Installation and Service ManualNOTE: See the Thermal restriction matrix for required fan support with air cooled and DLC configurations.
- RequirementA general rule that covers this part through its attributes
This riser configuration requires two processors (Table 14).
Parts on the other side: NO RSRR1B+R2A+R3B+R4BR1Q+R2A+R3B+R4QR1P+R2A+R3B+R4P (HL)R1P+R2A+R3B+R4P (FL)R1P+R2A+R3B+R4R (HL)R1R+R2A+R3A+R4P (HL)R1R+R2A+R3A+R4P (FL)R2A+R4QR1Q+R2A+R4QR1 Paddle + R2A + R3B + R4 Paddle
Source: dell-r760-tg — page 34
Dell PowerEdge R760 Technical GuideTable 14. PCIe Riser Configurations Config No. Riser configuration No. of Processors PERC type supported Rear storage possible
Source: dell-r760-tg — page 34
Dell PowerEdge R760 Technical Guide0 NO RSR 2 Front PERC No