Related rules (11)
- Allowed quantitiesThe rule applies only when this part is selected
Xeon Max processor: 1, 2, 4, 8 or 16 DIMMs per processor.
Source: dell-r760-ism — page 227
Dell PowerEdge R760 Installation and Service ManualTable 152. Memory population rules for Xeon Max processor
Source: dell-r760-ism — page 227
Dell PowerEdge R760 Installation and Service Manual1, 2, 4, 8, or 16 DIMMs are allowed.
- WarningThe rule applies only when this part is selected
Dell states 6400/5600 MT/s RDIMMs are applicable for 5th Gen processors; the only rows of 'Supported DIMMs' are 6400 MT/s, the 4800 MT/s RDIMMs for 4th Gen appear only in the memory matrix - confirm memory for a 4th Gen processor.
Source: dell-r760-tg — page 20
Dell PowerEdge R760 Technical GuideNOTE: 6400/5600 MT/s RDIMMs are applicable for 5th Gen Intel® Xeon® Scalable Processors.
Source: dell-r760-tg — page 19
Dell PowerEdge R760 Technical GuideTable 6. Supported DIMMs
- WarningThe rule applies only when this part is selected
This option needs expert review (see the item note).
Source: dell-r760-ism — page 39
Dell PowerEdge R760 Installation and Service ManualNOTE: See the Thermal restriction matrix for required fan support with air cooled and DLC configurations.
Source: dell-r760-tg — page 20
Dell PowerEdge R760 Technical GuideNOTE: 6400/5600 MT/s RDIMMs are applicable for 5th Gen Intel® Xeon® Scalable Processors.
- IncompatibilityA general rule that covers this part through its attributes
The STD heat sink supports processors up to 165 W only.
Parts on the other side: STD HSK
Source: dell-r760-tg — page 72
Dell PowerEdge R760 Technical GuideSTD HSK ≤ 165 W (supports only 2.5-inch drives and non-GPU configuration)
- IncompatibilityA general rule that covers this part through its attributes
With 3.5-inch drives the 2U HPR heat sink supports 125 W-250 W processors.
Parts on the other side: 2U HPR HSK
Source: dell-r760-tg — page 72
Dell PowerEdge R760 Technical Guide2U HPR HSK 125 W–250 W (supports 3.5-inch drives and non-GPU configuration) 165 W–350 W (supports 2.5-inch drives and non-GPU configuration)
- RequirementA general rule that covers this part through its attributes
GPU configurations with 24 front 2.5-inch bays (24 x 2.5 SAS, 16 SAS + 8 NVMe, 24 x 2.5 NVMe): 350 W processors are 'Required DLC' in Dell's GPU thermal matrices - one DLC module per processor.
Parts on the other side: DLC
Source: dell-r760-tg — page 78
Dell PowerEdge R760 Technical GuideTable 43. Thermal restriction matrix for GPU configurations
Source: dell-r760-tg — page 79
Dell PowerEdge R760 Technical Guide24 x 2.5- inch SAS 16 x 2.5- inch SAS + 8 x 2.5- inch NVMe 24 x 2.5- inch NVMe
- RequirementA general rule that covers this part through its attributes
Select one heat sink (STD, 2U HPR or L-type per the heat sink matrix) or the DLC module per processor.
Parts on the other side: STD HSK2U HPR HSKL-type HSKDLC
Source: dell-r760-tg — page 72
Dell PowerEdge R760 Technical GuideTable 38. Processor and heat sink matrix Heat sink Processor TDP
Source: dell-r760-ism — page 368
Dell PowerEdge R760 Installation and Service ManualHeat sinks L-type heat sink for processor 1 and processor 2 RC 3-2, 5-2: 2 RC 10-2: 1
- RequirementA general rule that covers this part through its attributes
12 x 3.5-inch configurations (with or without rear drives): processors of 270 W and above are 'Required DLC' in Dell's thermal matrices - one DLC module per processor.
Parts on the other side: DLC
Source: dell-r760-tg — page 73
Dell PowerEdge R760 Technical GuideTable 40. Thermal restriction matrix for air cooled configuration
Source: dell-r760-tg — page 74
Dell PowerEdge R760 Technical Guide6444Y 270 W² 32 75 HPR SLVR HPR SLV R HPR SLVR HPR SLVR HP R SL VR HPR SLVR HPR SLVR HPR GOL D Req uire d DLC Require d DLC 35°C (95°F)
- RequirementA general rule that covers this part through its attributes
Cooling fans must be selected; the fan type depends on processor TDP, storage, rear drives and GPU per Dell's thermal matrix (expert review).
Source: dell-r760-ism — page 38
Dell PowerEdge R760 Installation and Service ManualThe PowerEdge R760 requires various cooling components that are based on processor TDP, storage modules, rear drives, and GPU to maintain optimum thermal performance.
Source: dell-r760-ism — page 39
Dell PowerEdge R760 Installation and Service ManualNOTE: See the Thermal restriction matrix for required fan support with air cooled and DLC configurations.
- IncompatibilityA general rule that covers this part through its attributes
12 x 3.5-inch with a rear module: CPU TDP greater than 270 W and specific Low Temperature-case CPUs are not supported.
Parts on the other side: 12 x 3.5" (SAS/SATA) w/ rear 2 x 2.5" (SAS/SATA)12 x 3.5" (SAS/SATA) w/ rear 2 x 2.5" NVMe Direct12 x 3.5" (SAS/SATA) + 4 x 2.5" (SAS/SATA)12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct)12 x 3.5" (SAS/SATA) + 4 x EDSFF E3.S (Gen5 x 4 NVMe Direct)
Source: dell-r760-ism — page 51
Dell PowerEdge R760 Installation and Service ManualNOTE: In 12 x 3.5-inch with rear module configuration, for CPU TDP greater than 270 W and specific Low Temperature- case CPUs are not supported.
- RequirementA general rule that covers this part through its attributes
This riser configuration requires two processors (Table 14).
Parts on the other side: NO RSRR1B+R2A+R3B+R4BR1Q+R2A+R3B+R4QR1P+R2A+R3B+R4P (HL)R1P+R2A+R3B+R4P (FL)R1P+R2A+R3B+R4R (HL)R1R+R2A+R3A+R4P (HL)R1R+R2A+R3A+R4P (FL)R2A+R4QR1Q+R2A+R4QR1 Paddle + R2A + R3B + R4 Paddle
Source: dell-r760-tg — page 34
Dell PowerEdge R760 Technical GuideTable 14. PCIe Riser Configurations Config No. Riser configuration No. of Processors PERC type supported Rear storage possible
Source: dell-r760-tg — page 34
Dell PowerEdge R760 Technical Guide0 NO RSR 2 Front PERC No