Related rules (29)
- WarningThe rule applies only when this part is selected
Dell documents 'two DW GPUs or six SW GPUs'; mixing DW and SW GPUs is not documented.
Source: dell-r760-ism — page 370
Dell PowerEdge R760 Installation and Service ManualNOTE: A maximum of two DW GPUs with power cables or a maximum of six SW GPUs are supported in a system based on riser configuration.
Source: dell-r760-tg — page 9
Dell PowerEdge R760 Technical GuideGPU Options Up to two double wide 350 W, or six single wide 75 W accelerators
- Maximum quantityThe rule limits this part
These cards are not listed in the card table of riser configuration 0 (NO RSR) in Dell's ISM and are not supported with it.
Source: dell-r760-ism — page 260
Dell PowerEdge R760 Installation and Service ManualTable 154. Configuration 0: No risers
Source: dell-r760-ism — page 260
Dell PowerEdge R760 Installation and Service ManualCard type Slot priority Maximum number of cards
- Maximum quantityThe rule limits this part
These cards are not listed in the card table of riser configuration 6 (R2A+R4Q) in Dell's ISM and are not supported with it.
Source: dell-r760-ism — page 278
Dell PowerEdge R760 Installation and Service ManualTable 162. Configuration 6: R2A+R4Q
Source: dell-r760-ism — page 278
Dell PowerEdge R760 Installation and Service ManualCard type Slot priority Maximum number of cards
- Maximum quantityThe rule limits this part
These cards are not listed in the card table of riser configuration 7/12 (R1Q+R2A+R4Q) in Dell's ISM and are not supported with it.
Source: dell-r760-ism — page 280
Dell PowerEdge R760 Installation and Service ManualTable 163. Configuration 7: R1Q+R2A+R4Q
Source: dell-r760-ism — page 280
Dell PowerEdge R760 Installation and Service ManualCard type Slot priority Maximum number of cards
- Maximum quantityThe rule limits this part
The selected riser configuration (0) has 0 PCIe slot(s) (ISM Table 153): GPUs + PCIe NICs + external controllers <= 0.
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule limits this part
The selected riser configuration (8, 10-1, 10-2) has 3 PCIe slot(s) (ISM Table 153): GPUs + PCIe NICs + external controllers <= 3.
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule limits this part
12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 8, 10-1, 10-2 slot cards + adapter <= 3.
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule limits this part
Front + adapter dual-controller base: with riser configuration 8, 10-1, 10-2 slot cards + internal controllers <= 4 (3 slots + the front PERC's integrated slot).
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule limits this part
The selected riser configuration (6, 9, 11) has 4 PCIe slot(s) (ISM Table 153): GPUs + PCIe NICs + external controllers <= 4.
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule limits this part
12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 6, 9, 11 slot cards + adapter <= 4.
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule limits this part
Front + adapter dual-controller base: with riser configuration 6, 9, 11 slot cards + internal controllers <= 5 (4 slots + the front PERC's integrated slot).
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule limits this part
The selected riser configuration (3-1, 3-2, 4-1, 5-1, 5-2, 7/12) has 6 PCIe slot(s) (ISM Table 153): GPUs + PCIe NICs + external controllers <= 6.
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule limits this part
12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 3-1, 3-2, 4-1, 5-1, 5-2, 7/12 slot cards + adapter <= 6.
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule limits this part
Front + adapter dual-controller base: with riser configuration 3-1, 3-2, 4-1, 5-1, 5-2, 7/12 slot cards + internal controllers <= 7 (6 slots + the front PERC's integrated slot).
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule limits this part
The selected riser configuration (1, 2) has 8 PCIe slot(s) (ISM Table 153): GPUs + PCIe NICs + external controllers <= 8.
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule limits this part
12 x 3.5-inch bases use a PERC Adapter in Riser 2 (one slot): with riser configuration 1, 2 slot cards + adapter <= 8.
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule limits this part
Front + adapter dual-controller base: with riser configuration 1, 2 slot cards + internal controllers <= 9 (8 slots + the front PERC's integrated slot).
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule limits this part
The selected riser configuration (6, 8, 10-1, 10-2, 11) has 2 full-height slot(s) (Table 153): GPUs + full-height PCIe NICs <= 2.
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule limits this part
The selected riser configuration (9) has 3 full-height slot(s) (Table 153): GPUs + full-height PCIe NICs <= 3.
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule limits this part
The selected riser configuration (3-1, 3-2, 4-1, 5-1, 5-2, 7/12) has 4 full-height slot(s) (Table 153): GPUs + full-height PCIe NICs <= 4.
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- Maximum quantityThe rule limits this part
The selected riser configuration (1, 2) has 6 full-height slot(s) (Table 153): GPUs + full-height PCIe NICs <= 6.
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualConfigurations Expansion card risers PCIe Slots Form factor Controlling processor
- IncompatibilityA general rule that covers this part through its attributes
The STD heat sink is for non-GPU configurations only.
Parts on the other side: STD HSK
Source: dell-r760-tg — page 72
Dell PowerEdge R760 Technical GuideSTD HSK ≤ 165 W (supports only 2.5-inch drives and non-GPU configuration)
Source: dell-r760-tg — page 72
Dell PowerEdge R760 Technical GuideL-type HSK Supports all GPU/FPGA configurations NOTE: All GPU/FGPA cards require 1U L-type HSK and GPU shroud.
- IncompatibilityA general rule that covers this part through its attributes
The 2U HPR heat sink is for non-GPU configurations; all GPU cards require the 1U L-type heat sink.
Parts on the other side: 2U HPR HSK
Source: dell-r760-tg — page 72
Dell PowerEdge R760 Technical Guide2U HPR HSK 125 W–250 W (supports 3.5-inch drives and non-GPU configuration) 165 W–350 W (supports 2.5-inch drives and non-GPU configuration)
Source: dell-r760-tg — page 72
Dell PowerEdge R760 Technical GuideL-type HSK Supports all GPU/FPGA configurations NOTE: All GPU/FGPA cards require 1U L-type HSK and GPU shroud.
- RequirementA general rule that covers this part through its attributes
All GPU cards require the 1U L-type heat sink and the GPU shroud (one per processor); where the GPU thermal matrix says 'Required DLC' the DLC module is used instead of the L-type heat sink.
Parts on the other side: L-type HSKDLC
Source: dell-r760-tg — page 72
Dell PowerEdge R760 Technical GuideL-type HSK Supports all GPU/FPGA configurations NOTE: All GPU/FGPA cards require 1U L-type HSK and GPU shroud.
Source: dell-r760-ism — page 368
Dell PowerEdge R760 Installation and Service ManualHeat sinks L-type heat sink for processor 1 and processor 2 RC 3-2, 5-2: 2 RC 10-2: 1
- RequirementA general rule that covers this part through its attributes
The L-type heat sink is for GPU/FPGA configurations; non-GPU configurations use the STD or 2U HPR heat sink per Dell's heat sink matrix.
Parts on the other side: L-type HSK
Source: dell-r760-tg — page 72
Dell PowerEdge R760 Technical GuideL-type HSK Supports all GPU/FPGA configurations NOTE: All GPU/FGPA cards require 1U L-type HSK and GPU shroud.
Source: dell-r760-tg — page 72
Dell PowerEdge R760 Technical GuideSTD HSK ≤ 165 W (supports only 2.5-inch drives and non-GPU configuration)
- IncompatibilityA general rule that covers this part through its attributes
12 x 3.5-inch and rear-drive configurations do not support a GPU card.
Parts on the other side: 12 x 3.5" (SAS/SATA)12 x 3.5" (SAS/SATA) w/ rear 2 x 2.5" (SAS/SATA)12 x 3.5" (SAS/SATA) w/ rear 2 x 2.5" NVMe Direct12 x 3.5" (SAS/SATA) + 4 x 2.5" (SAS/SATA)12 x 3.5" (SAS/SATA) + 4 x 2.5" (NVMe Direct)12 x 3.5" (SAS/SATA) + 4 x EDSFF E3.S (Gen5 x 4 NVMe Direct)24 x 2.5" (SAS4/SATA) + 2 x 2.5" (NVMe Direct)24 x 2.5"(SAS4/SATA) + 2 x 2.5" (SAS/SATA)24 x 2.5"(SAS4/SATA) + 4 x 2.5" (SAS/SATA)24 x 2.5" (SAS4/SATA) + 4 x 2.5" (NVMe Direct)24 x 2.5" + 2 x 2.5" (SAS4/SATA) - Dual Controller24 x 2.5" (SAS4/SATA) with 4 x Universal slots (SAS/SATA HWRAID + NVMe Direct) + 4 x 2.5" (SAS4/SATA)
Source: dell-r760-ism — page 369
Dell PowerEdge R760 Installation and Service ManualNOTE: 12 x 3.5-inch and rear drive configuration systems do not support a GPU card.
- RequirementA general rule that covers this part through its attributes
GPU configurations support only HPR Gold fans (six, per the GPU kit).
Parts on the other side: HPR Gold
Source: dell-r760-tg — page 80
Dell PowerEdge R760 Technical GuideNOTE: GPU configuration supports only High performance Gold (HPR Gold) fan.
Source: dell-r760-ism — page 368
Dell PowerEdge R760 Installation and Service ManualFans HPR GOLD fan 6
- IncompatibilityA general rule that covers this part through its attributes
GPU configurations support only HPR Gold fans.
Parts on the other side: STDHPR Silver
Source: dell-r760-tg — page 80
Dell PowerEdge R760 Technical GuideNOTE: GPU configuration supports only High performance Gold (HPR Gold) fan.
- RequirementA general rule that covers this part through its attributes
GPUs install in riser slots and their maximum depends on the riser configuration: select a riser configuration that supports GPUs.
Parts on the other side: R1B+R2A+R3B+R4BR1Q+R2A+R3B+R4QR1P+R2A+R3B+R4P (HL)R1P+R2A+R3B+R4P (FL)R1P+R2A+R3B+R4R (HL)R1R+R2A+R3A+R4P (HL)R1R+R2A+R3A+R4P (FL)R1B+R2AR1Q+R2A+R4RR1P+R2A+R4R (HL)R1P+R2A+R4R (FL)R1 Paddle + R2A + R3B + R4 Paddle
Source: dell-r760-ism — page 370
Dell PowerEdge R760 Installation and Service ManualNOTE: A maximum of two DW GPUs with power cables or a maximum of six SW GPUs are supported in a system based on riser configuration.
Source: dell-r760-ism — page 256
Dell PowerEdge R760 Installation and Service ManualTable 153. Expansion card riser configurations